ArticleVeterinary ophthalmology2025
Validation of the EYEMATE-SC Suprachoroidal Pressure Transducer for Telemetric Measurement of Intraocular Pressure in Normal Ex Vivo Canine and Equine Globes-Preliminary Results.
Article in Veterinary ophthalmology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
objectiveTo determine the accuracy of the EYEMATE-SC suprachoroidal tracer for telemetric tonometry in canine and equine globes. PROCEDURES: The EYEMATE-SC sensor (7.8 mm × 3.8 mm × 1 mm) was implanted in the suprachoroidal space of four freshly enucleated normal canine and two normal equine eyes. The anterior chambers were cannulated and connected to a reservoir of Plasma-Lyte A and a manometer. Starting at a manometric IOP of 5 mmHg, the pressure was progressively increased to 80 mmHg by raising the reservoir. At each setpoint (5, 10, 15, 20, 25, 30, 35, 40, 50, 60, 70, and 80 mmHg), triplicate telemetric measurements were taken with the EYEMATE-SC using a portable reading device for telemetric pressure transmission via a radiofrequency band. These measurements were compared to manometric pressure by linear regression analysis.
resultsA strong positive linear regression was observed between EYEMATE-SC and manometry IOPs in both canine and equine eyes (canine: R
conclusionsMeasuring canine and equine IOPs from the suprachoroidal space using the EYEMATE-SC provided accurate results over an extensive range of pressures in ex vivo globes. This telemetric sensor could assist with long-term, frequent tonometry by pet owners and clinicians following in vivo testing. Although the sensor could not detect pressures above 70 mmHg, this flaw was not considered clinically relevant.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.