ArticleEuropean radiology2026
Artificial intelligence as an independent reader of risk-dominant lung nodules: influence of CT reconstruction parameters.
Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Development and internal validation of a clinical nomogram incorporating quantitative CT features for predicting malignancy in pulmonary nodules ≤ 3 cm.BMC medical imaging · 2026Article
- A radiomics nomogram integrated with radiological features for preoperative prediction of lung nodule invasiveness: comparison with Lung-RADS.Translational lung cancer research · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
objectivesTo assess the impact of reconstruction parameters on AI's performance in detecting and classifying risk-dominant nodules in a baseline low-dose CT (LDCT) screening among a Chinese general population. MATERIALS AND
methodsBaseline LDCT scans from 300 consecutive participants in the Netherlands and China Big-3 (NELCIN-B3) trial were included. AI analyzed each scan reconstructed with four settings: 1 mm/0.7 mm thickness/interval with medium-soft and hard kernels (D45f/1 mm, B80f/1 mm) and 2 mm/1 mm with soft and medium-soft kernels (B30f/2 mm, D45f/2 mm). Reading results from consensus read by two radiologists served as reference standard. At scan level, inter-reader agreement between AI and reference standard, sensitivity, and specificity in determining the presence of a risk-dominant nodule were evaluated. For reference-standard risk-dominant nodules, nodule detection rate, and agreement in nodule type classification between AI and reference standard were assessed.
resultsAI-D45f/1 mm demonstrated a significantly higher sensitivity than AI-B80f/1 mm in determining the presence of a risk-dominant nodule per scan (77.5% vs. 31.5%, p < 0.0001). For reference-standard risk-dominant nodules (111/300, 37.0%), kernel variations (AI-D45f/1 mm vs. AI-B80f/1 mm) did not significantly affect AI's nodule detection rate (87.4% vs. 82.0%, p = 0.26) but substantially influenced the agreement in nodule type classification between AI and reference standard (87.7% [50/57] vs. 17.7% [11/62], p < 0.0001). Change in thickness/interval (AI-D45f/1 mm vs. AI-D45f/2 mm) had no substantial influence on any of AI's performance (p > 0.05).
conclusionVariations in reconstruction kernels significantly affected AI's performance in risk-dominant nodule type classification, but not nodule detection. Ensuring consistency with radiologist-preferred kernels significantly improved agreement in nodule type classification and may help integrate AI more smoothly into clinical workflows. KEY POINTS: Question Patient management in lung cancer screening depends on the risk-dominant nodule, yet no prior studies have assessed the impact of reconstruction parameters on AI performance for these nodules. Findings The difference between reconstruction kernels (AI-D45f/1 mm vs. AI-B80f/1 mm, or AI-B30f/2 mm vs. AI-D45f/2 mm) significantly affected AI's performance in risk-dominant nodule type classification, but not nodule detection. Clinical relevance The use of kernel for AI consistent with radiologist's choice is likely to improve the overall performance of AI-based CAD systems as an independent reader and support greater clinical acceptance and integration of AI tools into routine practice.