Evidence map›Paper›PMID 40881134›Full record

ArticleAnalytical letters2025

Quantitation of Arsenic in biological matrices: Use of Sector Field Inductively Coupled Plasma-Mass Spectrometry for Improved Accuracy and Specificity.

Chamindu Liyanapatirana, Frank X Weber, James M Harrington, Laura G Haines, Reshan A Fernando, Keith E Levine, Suramya Waidyanatha

Abstract read
In one paragraph

Article in Analytical letters, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chamindu LiyanapatiranaRTI International, Research Triangle Park, NC, United States.
Frank X WeberRTI International, Research Triangle Park, NC, United States.
James M HarringtonRTI International, Research Triangle Park, NC, United States.
Laura G HainesRTI International, Research Triangle Park, NC, United States.
Reshan A FernandoRTI International, Research Triangle Park, NC, United States.
Keith E LevineRTI International, Research Triangle Park, NC, United States.
Suramya WaidyanathaDivision of Translational Toxicology, NIEHS, Research Triangle Park, NC, United States.

Funding

Cardiovascular Health Effects Innovation Research ProgramZIAES103382 · NIEHS · NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES · PI BEVERLY, BRANDIESE · 2022 to 2025
$6.7M
Chemistry Services Supporting the Division of Translational ToxicologyZICES103391 · NIEHS · NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES · PI WAIDYANATHA, SURAMYA · 2023 to 2025
$3.1M
Intramural NIH HHS Z99 ES999999Intramural NIH HHS ZIA ES103382Intramural NIH HHS ZIC ES103391NICHD NIH HHS HHSN273201400022CNIEHS NIH HHS HHSN273201400022C
6 · The paper itself

Abstract

Arsenic (As) and As-containing compounds have a wide array of applications in medicine, industry, and agriculture and has been associated with adverse health outcomes. In support of studies investigating the toxicity and toxicokinetic behavior of arsenic compounds, we developed and validated a high-resolution sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) method to quantitate total arsenic in Sprague-Dawley (SD) rat plasma and heart. Primary matrix standard curves prepared in male SD rat plasma were linear (r ≥ 0.999) over the range of 5 to 1250 ng As/mL plasma with accuracy determined as relative error (RE) was ≤ ±20% at the lower limit of quantitation (LLOQ) of 5 ng/mL and ≤ ±15% for all other concentrations. The method limit of detection (LOD) was 0.728 ng/mL plasma. Mean extraction recovery was 96.7%, with a relative standard deviation (RSD) of 4.0%. The method demonstrated acceptable inter- (≤ ±7.3% RE and ≤ 8.0% RSD) and intra-day (≤ ±14.9% RE and ≤ 6.8% RSD) accuracy and precision. Method selectivity was ≤ 20% of the response for the LLOQ. Method performance was also evaluated in SD rat heart by preparing QC samples in heart homogenate and quantifying using plasma calibration curve. The mean RE value was -3.8% and the RSD value was 3.4% demonstrating that the method is suitable for quantitation of arsenic in rat heart.

Indexed as

ArsenicBioanalytical Method validationHigh resolution sector field inductively coupled plasma-mass spectrometry (ICP-MS)Polyatomic interferencesRat plasma and heart tissues

Identifiers

PMID40881134
PMCPMC12383451

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.