Evidence map›Paper›PMID 40881002›Full record

ArticleChemical & biomedical imaging2025

Efficient 3D Biomedical Image Segmentation by Parallelly Multiscale Transformer-CNN Aggregation Network.

Wei Liu, Yuxiao He, Tiantian Man, Fulin Zhu, Qiaoliang Chen, Yaqi Huang, Xuyu Feng, Bin Li, Ying Wan, Jian He and 1 more

Abstract read
In one paragraph

Article in Chemical & biomedical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Wei LiuSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Yuxiao HeSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Tiantian ManSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Fulin ZhuSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Qiaoliang ChenDepartment of Nuclear Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
Yaqi HuangSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Xuyu FengSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Bin LiSchool of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Ying WanSchool of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.ORCID https://orcid.org/0000-0002-3409-0492
Jian HeDepartment of Nuclear Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
Shengyuan DengSchool of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.ORCID https://orcid.org/0000-0002-6382-0976

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate and automated segmentation of 3D biomedical images is a sophisticated imperative in clinical diagnosis, imaging-guided surgery, and prognosis judgment. Although the burgeoning of deep learning technologies has fostered smart segmentators, the successive and simultaneous garnering global and local features still remains challenging, which is essential for an exact and efficient imageological assay. To this end, a segmentation solution dubbed the mixed parallel shunted transformer (MPSTrans) is developed here, highlighting 3D-MPST blocks in a U-form framework. It enabled not only comprehensive characteristic capture and multiscale slice synchronization but also deep supervision in the decoder to facilitate the fetching of hierarchical representations. Performing on an unpublished colon cancer data set, this model achieved an impressive increase in dice similarity coefficient (DSC) and a 1.718 mm decease in Hausdorff distance at 95% (HD95), alongside a substantial shrink of computational load of 56.7% in giga floating-point operations per second (GFLOPs). Meanwhile, MPSTrans outperforms other mainstream methods (Swin UNETR, UNETR, nnU-Net, PHTrans, and 3D U-Net) on three public multiorgan (aorta, gallbladder, kidney, liver, pancreas, spleen, stomach, etc.) and multimodal (CT, PET-CT, and MRI) data sets of medical segmentation decathlon (MSD) brain tumor, multiatlas labeling beyond cranial vault (BCV), and automated cardiac diagnosis challenge (ACDC), accentuating its adaptability. These results reflect the potential of MPSTrans to advance the state-of-the-art in biomedical imaging analysis, which would offer a robust tool for enhanced diagnostic capacity.

Indexed as

3D biomedical image segmentationconvolutional neural networksmultiscale feature extractionparallel architectureshunted transformer

Identifiers

PMID40881002
PMCPMC12381746

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.