Evidence map›Paper›PMID 40880675›Full record

ArticleCase reports in gastroenterology

Repeated Delayed Bleeding following Treatment for a Pancreatic Pseudocyst during Lumen-Apposing Metal Stent Placement: A Case Report.

Hiroyuki Ito, Yosuke Tazawa, Yuji Omura, Toru Yamaguchi, Tsubomi Chou, Ayano Ito, Shingo Tsuda, Junko Nagata, Shunji Hirose, Shunsuke Kamei and 2 more

Abstract readCase Reports
In one paragraph

Article in Case reports in gastroenterology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Hiroyuki ItoDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Yosuke TazawaDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Yuji OmuraDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Toru YamaguchiDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Tsubomi ChouDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Ayano ItoDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Shingo TsudaDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Junko NagataDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Shunji HiroseDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.
Shunsuke KameiDepartment of Radiology, Tokai University Hachioji Hospital, Tokyo, Japan.
Yukihisa OgawaDepartment of Radiology, Tokai University Hachioji Hospital, Tokyo, Japan.
Takayoshi SuzukiDepartment of Gastroenterology, Tokai University Hachioji Hospital, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The lumen-apposing metal stent (LAMS) is a novel prosthesis for fistula formation between the gastrointestinal and cyst walls. Bleeding complications occur in 10% of cases mostly during LAMS placement. We present a case of recurrent bleeding following LAMS placement. Case Presentation: A 47-year-old male was admitted to a local hospital for acute pancreatitis and subsequently referred for endoscopic drainage because of an enlarging pseudocyst near the tail of the pancreas. Treatment involved LAMS and endoscopic ultrasound-guided transmural drainage. Posttreatment computed tomography revealed cyst shrinkage; however, upper gastrointestinal bleeding was noted after discharge. Endoscopy identified bleeding within the fistula, which was controlled by spraying an absorbable local hemostatic agent into the cavity. After ensuring the absence of recurrent bleeding for approximately 1 month, the LAMS was removed under endoscopy. Following LAMS removal, arterial bleeding was observed within the cavity, prompting an emergency angiography. Angiography revealed bleeding from a pseudoaneurysm of the splenic artery, which was treated with coil embolization. No rebleeding occurred after the procedure. Conclusion: Bleeding 1 week after placement or during removal is rare. However, following LAMS placement, there is a risk of bleeding until removal, with arterial bleeding often occurring at the time of removal. Therefore, it is necessary to establish a system that allows for prompt vascular embolization treatment.

Indexed as

Bleeding complicationEndoscopic ultrasound-guided transmural drainageLumen-apposing metal stentPancreatic pseudocyst

Identifiers

PMID40880675
PMCPMC11949512

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.