Evidence map›Paper›PMID 40879998›Full record

ArticleJournal of the Association for Research in Otolaryngology : JARO2025

An Integrated System for Comprehensive Mouse Peripheral Vestibular Function Evaluation Based on Vestibulo-ocular Reflex.

Tong Zhao, Shijie Xiao, Wenda Liu, Jinhao Zhong, Binxian Sun, Fangyi Chen

Abstract read
In one paragraph

Article in Journal of the Association for Research in Otolaryngology : JARO, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tong Zhao *Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, 518055, China.
Shijie Xiao *Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, 518055, China.
Wenda LiuGiant Technologies Co., Ltd, Shenzhen, Guangdong, 518055, China.
Jinhao ZhongDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, 518055, China.
Binxian SunDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, 518055, China.
Fangyi ChenDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, 518055, China. chenfy@sustech.edu.cn.ORCID http://orcid.org/0000-0002-5024-6215

Funding

Key Technologies Research and Development Program 2023YFF1203505Key Technologies Research and Development Program 2024YFC2417900Shenzhen Municipal Science and Technology Innovation Council 202110293000007Shenzhen Science and Technology Innovation Program KJZD20230923114909019
6 · The paper itself

Abstract

purposeIn the fields of both vestibular and auditory research, reliable vestibular function tests are essential. However, unlike the auditory function tests, which use standard Auditory Brainstem Response (ABR) equipment, there is no equivalent widely adopted apparatus for vestibular tests. Vestibulo-ocular reflexes (VORs) are the compensatory ocular reflexes that ensure stable vision during head motion. VORs are widely used in clinics to diagnose vestibular deficits. In the research, VORs have been used by various groups to evaluate the mouse vestibular function. However, the effectiveness of VOR tests has not been systematically evaluated with appropriate mouse models, and the lack of commercial equipment hampers its accessibility, confining vestibular testing to a select few labs.

methodsIn this study, we developed an integrated and surgery-free instrument system with both angular VOR (aVOR) and off-vertical axis rotation (OVAR) modes for evaluating mouse vestibular function. In addition, the eye rotation calibrations used in this study standardize the data between instruments. To demonstrate its validity and efficacy of the testing equipment, we evaluated four mouse models, including both genders, with peripheral vestibular deficits: 1) mice injected with the vestibulotoxic drug 3,3'-iminodiproprionitrile (IDPN, 2 mg/g and 4 mg/g, 3 male/3 female per group); 2) Critical MET-related mutant mice (Cdh23

resultsThe results showed: 1) Quantification of vestibular deficits can be achieved as a daily routine; 2) Both the horizontal semicircular canal and otolith organs can be assessed, respectively; and 3) The lesion side of UVL can be identified.

conclusionThese test results reveal the potential of our system as standard equipment for evaluating common vestibular deficits in mice.

Indexed as

Reflex, Vestibulo-OcularVestibular Function TestsAnimalsFemaleMaleMiceMice, Inbred C57BLComprehensive mouse vestibular function evaluationOtolith organSemicircular canalsVestibular deficit mouse modelsVestibulo-ocular reflexes (VORs)

Identifiers

PMID40879998
PMCPMC12528608

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.