Evidence map›Paper›PMID 40878616›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2026

A novel knee implant for total knee arthroplasty meets expectations at 10 years. First long-term follow-up report of clinical outcomes and survivorship.

Alice Montagna, Marina Marescalchi, Virginia Cinelli, Rudy Sangaletti, Luca Andriollo, Francesco Benazzo, Stefano Marco Paolo Rossi

Abstract read
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alice MontagnaU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Marina MarescalchiU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Virginia CinelliU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Rudy SangalettiU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Luca AndriolloU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Francesco BenazzoU.O.C Ortopedia e Traumatologia Fondazione Poliambulanza, Brescia, Italy.
Stefano Marco Paolo RossiUnità di Chirurgia Robotica U.O.C Ortopedia e Traumatologia, Fondazione Poliambulanza, Brescia, Italy.ORCID https://orcid.org/0000-0003-4395-8457

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAchieving a "forgotten knee" after total knee arthroplasty (TKA) remains a primary goal in modern knee replacement surgery. Anatomic implant designs aim to replicate native knee anatomy and kinematics, potentially improving patient satisfaction and functional outcomes. This study evaluates the long-term clinical outcome and survivorship of the Persona Knee System at a minimum follow-up of 10 years.

methods116 TKAs performed using the Persona Posterior Stabilised (PS) Knee System (Zimmer Biomet, Warsaw, Indiana, USA) between 2013 and 2014 at a high-volume orthopaedic centre were prospectively followed and retrospectively analysed. Clinical outcomes were assessed using patient-reported outcome measures (PROMs), including the Forgotten Joint Score-12 (FJS-12), Oxford Knee Score (OKS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC). Implant survivorship was determined using Kaplan-Meier analysis, and complication rates were recorded.

resultsAt a mean follow-up of 11.1 years, 116 knees were available for analysis. Patients were assessed clinically and radiographically at 1, 3 and 6 months postoperatively, and then annually, with a mean follow-up of 11.1 years. The mean FJS-12 was 69.52 (SD 12.21, range 15-88), indicating a high level of joint awareness reduction. The OKS and WOMAC scores significantly improved postoperatively, with mean final values of 38.63 (SD 7.99, range 7-48) and 25.29 (SD 16.97, range 4-91), respectively. Radiological analysis demonstrated accurate and stable implant positioning, with no progressive radiolucent lines in non-revised cases. Kaplan-Meier survival analysis showed a 95.7% (SD 1.9%) implant survival rate. The revision rate was 4.3%, with aseptic loosening and persistent painful prosthesis as the primary causes.

conclusionThe anatomic design of the Persona Knee System provides excellent long-term clinical outcomes, high patient satisfaction, and sustained implant durability. Future research should further investigate patient-specific factors and surgical refinements to optimise long-term outcomes in TKA. LEVEL OF EVIDENCE: Level III.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleMiddle AgedPatient Reported Outcome MeasuresPatient SatisfactionProsthesis DesignProsthesis FailureRetrospective StudiesTreatment OutcomeJ‐curvenew designsnovel implantposterior stabilisedtotal knee replacement

Identifiers

PMID40878616
PMCPMC13037349

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.