Evidence map›Paper›PMID 40877733›Full record

ArticleCardiovascular engineering and technology2025

Credibility Assessment of the Patient-Specific Modeling of the Aneurysmal Ascending Thoracic Aorta: Verification, Validation and Uncertainty Quantification.

Roberta Scuoppo, Chiara Catalano, Fabrizio Crascì, Salvatore Pasta

Abstract readValidation Study
In one paragraph

Article in Cardiovascular engineering and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Roberta ScuoppoDepartment of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy.
Chiara CatalanoDepartment of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy.
Fabrizio CrascìDepartment of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy.
Salvatore PastaDepartment of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy. salvatore.pasta@unipa.it.ORCID 0000-0002-4841-2560

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeComputational modeling holds promise in predicting patient-specific outcomes and guiding clinical decision-making. The patient-specific model forming the basis of a digital twin can be considered biomedical software, thereby necessitating trust in its predictive accuracy.

methodsThis study applies the ASME V&V40 framework to demonstrate the credibility of patient-specific models of aneurysmal thoracic ascending aorta (ATAA) biomechanics. A comprehensive verification, validation, and uncertainty quantification process was performed to evaluate the accuracy of the patient-specific ATAA model.

resultsAfter implementing the ASME V&V40 standard, the verification errors on the model inputs (i.e., material parameters and hemodynamic variables) resulted in relative errors (RE) < 1%. Validation and its uncertainty quantification of the output aneurysm diameter response showed area metric errors below 5% in the majority of cases, highlighting the accuracy of the patient-specific ATAA model against the clinical comparator. Uncertainties in wall stress predictions due to model inputs were also quantified by probability density functions. Sensitivity analysis revealed that the unknown value of aneurysm wall thickness drives the model output at the highest extent.

conclusionsThese findings contribute to a standardized methodology for evaluating the credibility of patient-specific models, enhancing their utility in computer-based clinical decision support systems for managing patients with ATAAs.

Indexed as

Aorta, ThoracicAortic Aneurysm, ThoracicComputed Tomography AngiographyHemodynamicsModels, CardiovascularPatient-Specific ModelingAortographyBiomechanical PhenomenaHumansMalePredictive Value of TestsReproducibility of ResultsStress, MechanicalUncertaintyASME VV40; aneurysm of ascending aortaComputational fluid dynamicsFinite-element analysisUncertainty quantification and validation

Identifiers

PMID40877733
PMCPMC12686058

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.