ArticleScientific reports2025
Transmission energy dispersive X-ray diffraction as a tool for the laboratory study of fast processes in metals.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Energy-Dispersive X-Ray Diffraction: Principles, Instrumentation and Emerging Applications.Materials (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
In this work, an in-situ study of phase transitions in low-carbon steel is presented. The phase changes were monitored by the transmission energy dispersive X-ray diffraction technique during the heating, annealing and quenching cycle of the sample under standard laboratory conditions. During energy dispersive X-ray diffraction, the sample volume was transmitted with a pencil beam generated by a standard polychromatic X-ray tube without any spectral filtering. Two-dimensional polychromatic diffraction images were acquired by a Timepix 3 pixelated detector. This detector is capable of achieving a throughput of up to 38 Mhits/s in continuous stream mode using USB 3.0 interface. For each detected photon, its position is known with an accuracy of 55 µm in the detector plane and its energy with a resolution of 4 keV at 60 keV. The recorded polychromatic data is then recomputed to get the equivalent monochromatic XRD pattern that would be produced using a monochromatic X-ray source. Thanks to the 90 kV voltage potential of the X-ray tube, the polychromatic pencil beam was able to pass through a highly attenuating sample made of 1.5 thick steel sheet. In addition, by utilizing the entire X-ray spectrum, the pencil beam has a sufficiently high brilliance to obtain XRD patterns rapidly enough to investigate relatively fast processes with temporal resolution of 10 s. It made to possible to analyze the phase transitions in a polycrystalline sample during its temperature treatment under standard laboratory conditions.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.