Evidence map›Paper›PMID 40875170›Full record

ArticleJournal of clinical monitoring and computing2026

Evaluation of accuracy, filter performance, and durability among capnography sampling lines: a bench study.

Terry L Jones, Denis Glozman, Harold Julius Augustus Oglesby, Jan Paul J Mulier

Abstract readEvaluation Study
In one paragraph

Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Terry L JonesSchool of Nursing, Virginia Commonwealth University, Richmond, VA, USA. tjones69@vcu.edu.
Denis GlozmanResearch and Development, Acute Care and Monitoring, Medtronic, Jerusalem, Israel.
Harold Julius Augustus OglesbyPulmonary Medicine, St. Joseph's/Candler Health, Savannah, GA, USA.
Jan Paul J MulierDepartment of Anesthesiology, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.

Funding

Medtronic, Jerusalem No Number
6 · The paper itself

Abstract

The aim of this bench study was to assess performance between currently available sidestream capnography sampling lines claiming compatibility with a Microstream™ enabled monitor system. A series of bench tests were performed on a selection of commercially available sampling lines (oral-nasal cannulas, PetCO2 masks, and procedural bite blocks) to assess PetCO2 accuracy, filter performance and mechanical durability. For each testing procedure, three separate sampling lines were assessed for five repetitions (n = 15 for each product). A 3D printed oral-nasal model connected to a lung simulator was set to two different breathing modes to simulate “normal” and “shallow” breathing. PetCO2 accuracy measurements were completed at both breathing modes to simulate a variety of clinical scenarios, including oxygen delivery. Filter performance and mechanical durability were assessed for cannula sampling lines. When evaluating PetCO2 accuracy across all sampling line types and breathing conditions, error estimates were lowest for matched-paired sampling lines, compared to cross-paired sampling lines. For oral-nasal cannulas, the matched-paired and three cross-paired performed within the system specification for “normal” breathing conditions. Split design oral-nasal cannulas consistently fell outside specifications under conditions of nasal obstruction. Five cross-paired filters clogged prior to expected threshold, with four demonstrating a clog capacity of less than half the expected value. Almost all sampling lines passed mechanical durability testing. Across all testing conditions, cross-paired sampling lines were observed to fall outside system specifications, suggesting that using sampling lines outside the Microstream™ family may disrupt accuracy of readings when using a Microstream™ enabled capnography monitor.

Indexed as

CapnographyCannulaCarbon DioxideEquipment DesignHumansMonitoring, PhysiologicOxygenPrinting, Three-DimensionalReproducibility of ResultsRespirationCarbon DioxideOxygenCapnographEnd-tidal carbon dioxideMonitoringRespiratory compromiseRespiratory depression

Identifiers

PMID40875170
PMCPMC12963109

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked