Evidence map›Paper›PMID 40874956›Full record

ArticleLangenbeck's archives of surgery2025

Versius surgical system: tips and tricks for OR setting and port placement for pelvic surgery, our experience in a multi-robotic referral centre.

Giorgia Gaia, Maria Chiara Sighinolfi, Margarita Afonina, Stefano Terzoni, Veronica Iannuzzi, Mauro Felline, Alessandro Morandi, Carlo Alboni, Antonio La Marca, Andrea Pisani Ceretti and 3 more

Abstract readMulticenter Study
In one paragraph

Article in Langenbeck's archives of surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Giorgia GaiaDivision of Obstetrics and Gynecology, San Paolo Hospital Medical School, ASST Santi Paolo E Carlo, Milan, Italy.
Maria Chiara SighinolfiDepartment of Urology, ASST Santi Paolo e Carlo, San Paolo University Hospital, Milan, Italy.
Margarita AfoninaDivision of Obstetrics and Gynecology, San Paolo Hospital Medical School, ASST Santi Paolo E Carlo, Milan, Italy. afoninamargarita@hotmail.com.
Stefano TerzoniDepartment of Biomedical Sciences for Health, Università degli Studi di Milano, Milan, Italy.
Veronica IannuzziDivision of Obstetrics and Gynecology, San Paolo Hospital Medical School, ASST Santi Paolo E Carlo, Milan, Italy.
Mauro FellineDivision of Obstetrics and Gynecology, San Carlo Hospital, ASST Santi Paolo E Carlo, Milan, Italy.
Alessandro MorandiDivision of Obstetrics and Gynecology, San Paolo Hospital Medical School, ASST Santi Paolo E Carlo, Milan, Italy.
Carlo AlboniObstetrics and Gynecology Unit, Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Modena, Italy.
Antonio La MarcaObstetrics and Gynecology Unit, Department of Medical and Surgical Sciences for Mother, Child and Adult, University of Modena and Reggio Emilia, Modena, Italy.
Andrea Pisani CerettiDepartment of General Surgery, ASST Santi Paolo e Carlo, San Paolo University Hospital, Milan, Italy.
Paolo Pietro BianchiDepartment of General Surgery, ASST Santi Paolo e Carlo, San Paolo University Hospital, Milan, Italy.
Bernardo RoccoDepartment of Urology, ASST Santi Paolo e Carlo, San Paolo University Hospital, Milan, Italy.
Anna Maria MarconiDivision of Obstetrics and Gynecology, San Paolo Hospital Medical School, ASST Santi Paolo E Carlo, Milan, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Versius surgical system (CMR Surgical, Cambridge, UK) is a new robotic platform introduced after the original patent of the DaVinci system expired; it has already been applied in different fields, including gynaecology. Unlike DaVinci, Versius has four independent bedside units (BSU), which must be individually positioned with adequate angles and distance to avoid collisions. Given this peculiarity and the shorter arm (30 cm) compared to the Da Vinci, investigating BSU positioning and port placement is mandatory. We aim to report technical tips and tricks for OR setup and port placement by analyzing our initial series with the Versius system for benign gynaecological conditions, thereby making the procedure easily reproducible. MATERIALS AND

methodsWe considered prospectively 19 patients undergoing robotic surgery for gynaecological diseases. Demographics, pre-surgical variables, intraoperative robotic events (number and characteristics of collisions, need for detaching instruments, and moving trays during surgery), and perioperative outcomes were collected. Factors impacting the occurrence of high-impact collisions (requiring the disconnection of instruments and restarting of the port training) were analyzed.

resultAll surgeries were carried out uneventfully and without conversion. Collisions of any type occurred in 16 out of 19 operations, including 11 high impact collisions. The distance between the trocars and the target organ is a factor that impacts the necessity to restart the system.

conclusionsVersius appeared to be a safe option for benign gynaecological surgery. Our experience suggests that a minimum distance of 19 cm from the bipolar operative trocar and the target organ, as well as a minimum distance of 15 cm between the scissors operative trocar and the target organ, is recommendable to avoid any collisions, or 11 and 9 cm to avoid high impact collisions.

conclusionsVersius appeared to be a safe option for benign gynaecological surgery. Our experience suggests that a minimum distance of 19 cm from the bipolar operative trocar and the target organ, as well as a minimum distance of 15 cm between the scissors operative trocar and the target organ, is recommendable to avoid any collisions, or 11 and 9 cm to avoid high impact collisions.

Indexed as

Genital Diseases, FemaleGynecologic Surgical ProceduresLaparoscopyRobotic Surgical ProceduresAdultAgedEquipment DesignFemaleHumansMiddle AgedProspective StudiesBenign gynaecological surgeryNew technologies: versius surgical systemOR setting.Port placement

Identifiers

PMID40874956
PMCPMC12394370

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.