Evidence map›Paper›PMID 40872402›Full record

ArticleMicromachines2025

Numerical Analysis of Microfluidic Motors Actuated by Reconfigurable Induced-Charge Electro-Osmotic Whirling Flow.

Jishun Shi, Zhipeng Song, Xiaoming Chen, Ziang Bai, Jialin Yu, Qihang Ye, Zipeng Yang, Jianru Qiao, Shuhua Ma, Kailiang Zhang

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jishun ShiSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Zhipeng SongSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Xiaoming ChenSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.ORCID 0009-0005-1816-8631
Ziang BaiSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Jialin YuSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Qihang YeSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Zipeng YangSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Jianru QiaoSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Shuhua MaSchool of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
Kailiang ZhangCollege of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150040, China.ORCID 0000-0002-4692-7421

Funding

Basic Research Project of Universities in Hebei Province 241790897AChina Postdoctoral Science Foundation 2024M750713Fundamental Research Funds for the Central Universities N2423026National Natural Science Foundation of China 62304034
6 · The paper itself

Abstract

The detection of proteins plays a key role in disease diagnosis and drug development. For this, we numerically investigated a novel microfluidic motor actuated by an induced-charge electro-osmotic (ICEO) whirling flow. An alternating current-flow field effect transistor is engineered to modulate the profiles of ICEO streaming to stimulate and adjust the whirling flow in the circle microfluidic chamber. Based on this, we studied the distribution of an ICEO whirling flow in the detection chamber by tuning the fixed potential on the gate electrodes by the simulations. Then, we established a fluid-structure interaction model to explore the influence of blade structure parameters on the rotation performance of microfluidic motors. In addition, we investigated the rotation dependence of microfluidic motors on the potential drop between two driving electrodes and fixed potential on the gate electrodes. Next, we numerically explored the capability of these microfluidic motors for the detection of low-abundance proteins. Finally, we studied the regulating effect of potential drops between the driving electrodes on the detection performance of microfluidic motors by numerical simulations. Microfluidic motors actuated by an ICEO whirling flow hold good potential in environmental monitoring and disease diagnosis for the outstanding advantages of flexible controllability, a simple structure, and gentle work condition.

Indexed as

induced-charge electro-osmosismicrofluidic motorsprotein detectionwhirling flow

Identifiers

PMID40872402
PMCPMC12388474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.