Evidence map›Paper›PMID 40871998›Full record

ArticleSensors (Basel, Switzerland)2025

Comparison of Techniques for Respiratory Rate Extraction from Electrocardiogram and Photoplethysmogram.

Alfonso Maria Ponsiglione, Michela Russo, Maria Giovanna Petrellese, Annalisa Letizia, Vincenza Tufano, Carlo Ricciardi, Annarita Tedesco, Francesco Amato, Maria Romano

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alfonso Maria PonsiglioneDepartment of Electrical Engineering and Information Technology, University of Naples Federico II, Via Claudio 22, 80125 Naples, Italy.ORCID 0000-0003-1346-515X
Michela RussoDepartment of Electrical Engineering and Information Technology, University of Naples Federico II, Via Claudio 22, 80125 Naples, Italy.ORCID 0000-0002-5874-6441
Maria Giovanna PetrelleseTeoresi S.p.A. Group, Via Perugia 24, 10152 Torino, Italy.
Annalisa LetiziaTeoresi S.p.A. Group, Via Perugia 24, 10152 Torino, Italy.
Vincenza TufanoTeoresi S.p.A. Group, Via Perugia 24, 10152 Torino, Italy.
Carlo RicciardiDepartment of Electrical Engineering and Information Technology, University of Naples Federico II, Via Claudio 22, 80125 Naples, Italy.ORCID 0000-0001-7290-6432
Annarita TedescoDepartment of Public Healtcare, University of Naples Federico II, Via S. Pansini, 80131 Napoli, Italy.ORCID 0000-0001-7242-701X
Francesco AmatoDepartment of Electrical Engineering and Information Technology, University of Naples Federico II, Via Claudio 22, 80125 Naples, Italy.ORCID 0000-0003-4384-1646
Maria RomanoDepartment of Electrical Engineering and Information Technology, University of Naples Federico II, Via Claudio 22, 80125 Naples, Italy.ORCID 0000-0003-1133-1115

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRespiratory rate (RR) is a key vital sign and one of the most sensitive indicators of physiological conditions, playing a crucial role in the early identification of clinical deterioration. The monitoring of RR using electrocardiography (ECG) and photoplethysmography (PPG) aims to overcome limitations of traditional methods in clinical settings.

methodsThe proposed approach extracts RR from ECG and PPG signals using different morphological and temporal features from publicly available datasets (iAMwell and Capnobase). The algorithm was used to develop and test with a selection of relevant ECG (e.g., R-peak, QRS area, and QRS slope) and PPG (amplitude and frequency modulation) characteristics.

resultsThe results show promising performance, with the ECG-derived signal using the R-peak-based method yielding the lowest error, with a mean absolute error of 0.99 breaths/min in the iAMwell dataset and 3.07 breaths/min in the Capnobase dataset. In comparison, the RR PPG-derived signal showed higher errors of 5.10 breaths/min in the iAMwell dataset and 10.66 breaths/min in the Capnobase dataset, for the FM and AM method, respectively. Bland-Altman analysis revealed a small negative bias, approximately -0.97 breaths/min for the iAMwell dataset (with limits of agreement from -2.62 to 0.95) and -1.16 breaths/min for the Capnobase dataset (limits of agreement from -3.37 to 1.10) in the intra-subject analysis. In the inter-subject analysis, the bias was -0.84 breaths/min (limits of agreement from -1.76 to 0.20) for iAMwell and -1.22 breaths/min (limits of agreement from -7.91 to 5.35) for Capnobase, indicating a slight underestimation. Conversely, the PPG-derived signal tended to overestimate RR, resulting in higher variability and reduced accuracy. These findings highlight the higher reliability of ECG-derived features for RR estimation in the analyzed datasets.

conclusionThis study suggests that the proposed approach could guide the design of cost-effective, non-invasive methods for continuous respiration monitoring, offering a reliable tool for detecting conditions like stress, anxiety, and sleep disorders.

Indexed as

ElectrocardiographyPhotoplethysmographyRespiratory RateAdultAlgorithmsFemaleHumansMaleSignal Processing, Computer-AssistedECG-derived respirationfeatures extractionPPG-derived respirationrespiratory ratesignal processing

Identifiers

PMID40871998
PMCPMC12390036

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.