Evidence map›Paper›PMID 40871959›Full record

ArticleSensors (Basel, Switzerland)2025

Dynamic Calibration of Quartz Flexure Accelerometers.

Xuan Sheng, Xizhe Wang, Wenying Chen, Yang Shu, Kai Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xuan ShengInstitute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Xizhe WangInstitute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Wenying ChenInstitute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Yang ShuInstitute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Kai ZhangInstitute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China.

Funding

National Natural Science Foundation of China - China Academy of Engineering Physics National Security Academic Fund (NSFC - CAEP NSAF) U2230121
6 · The paper itself

Abstract

The dynamic behavior of quartz flexure accelerometers remains a subject of ongoing investigation, particularly in areas such as theoretical modeling, standardization, calibration methodology, and performance evaluation. To address the limitation of conventional static calibration models in accurately representing accelerometer responses under dynamic acceleration excitation, a dynamic calibration model is proposed. A mathematical model is first developed based on the physical mechanism of the accelerometer, characterizing its intrinsic dynamic response. Simulation-based analysis demonstrates that the proposed dynamic model offers significantly improved accuracy compared to traditional static approaches. Furthermore, a dynamic calibration method leveraging a dual-axis precision centrifuge is designed and validated. The results confirm that the proposed approach enables the precise calibration of quartz flexure accelerometers in accordance with the dynamic model. The calibration of the dynamic parameter yields a relative standard deviation of -0.048%.

Indexed as

calibration methoddual-axis precision centrifugedynamic behaviorquartz flexure accelerometers

Identifiers

PMID40871959
PMCPMC12389905

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.