ArticleSensors (Basel, Switzerland)2025
A Low-Cost Device for Measuring Non-Nutritive Sucking in Newborns.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Non-nutritive sucking (NNS) is an instinctive behavior in newborns, consisting of two stages: sucking and expression. It plays a critical role in preparing the infant for oral feeding. In neonatal and pediatric units, NNS assessment is routinely performed to determine feeding readiness. However, these evaluations are often subjective and rely heavily on the clinician's experience. While other medical devices that support the development of NNS skills exist, they are not specifically designed for the comprehensive assessment of NNS, and their high cost limits accessibility for many hospitals and tertiary care units globally. This paper presents the development and pilot testing of a low-cost, portable device and accompanying software for assessing NNS in newborns hospitalized in neonatal care units. Methods: The device uses force-sensitive resistors to capture expression pressure and a differential pressure sensor to measure NNS. Data were acquired through the analog-digital converter of a microcontroller and transmitted via Bluetooth for real-time graphical analysis. Pilot testing was conducted with six hospitalized preterm newborns, measuring intensity, number of bursts, and sucks per burst. Results demonstrated that the system reliably captures both stages of NNS. Significance: This device provides an affordable, portable solution to support clinical decision-making in clinical units, facilitating accurate, objective monitoring of feeding readiness and developmental progression.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.