Evidence map›Paper›PMID 40871943›Full record

ArticleSensors (Basel, Switzerland)2025

A Low-Cost Device for Measuring Non-Nutritive Sucking in Newborns.

Sebastian Lobos, Eyleen Spencer, Pablo Reyes, Alejandro Weinstein, Jana Stojanova, Felipe Retamal-Walter

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sebastian LobosPhD Program in Health Sciences and Engineering, Universidad de Valparaíso, Valparaíso 2540064, Chile.ORCID 0000-0002-4870-0474
Eyleen SpencerSchool of Biomedical Engineering, Faculty of Engineering, Universidad de Valparaíso, Valparaíso 2362905, Chile.ORCID 0009-0003-9811-7863
Pablo ReyesSchool of Biomedical Engineering, Faculty of Engineering, Universidad de Valparaíso, Valparaíso 2362905, Chile.ORCID 0000-0001-8218-9852
Alejandro WeinsteinDepartment of Electronic Engineering, Universidad Técnica Federico Santa Maria, Valparaíso 2390123, Chile.ORCID 0000-0003-1486-7003
Jana StojanovaDepartment of Clinical Pharmacology and Toxicology, St. Vincent's Hospital, Sydney, NSW 2010, Australia.ORCID 0000-0003-4812-5745
Felipe Retamal-WalterSchool of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, QLD 4072, Australia.ORCID 0000-0001-7690-2025

Funding

Agencia Nacional de Investigación y Desarrollo BASAL AFB240002Agencia Nacional de Investigación y Desarrollo FONDECYT Regular 1231132
6 · The paper itself

Abstract

Non-nutritive sucking (NNS) is an instinctive behavior in newborns, consisting of two stages: sucking and expression. It plays a critical role in preparing the infant for oral feeding. In neonatal and pediatric units, NNS assessment is routinely performed to determine feeding readiness. However, these evaluations are often subjective and rely heavily on the clinician's experience. While other medical devices that support the development of NNS skills exist, they are not specifically designed for the comprehensive assessment of NNS, and their high cost limits accessibility for many hospitals and tertiary care units globally. This paper presents the development and pilot testing of a low-cost, portable device and accompanying software for assessing NNS in newborns hospitalized in neonatal care units. Methods: The device uses force-sensitive resistors to capture expression pressure and a differential pressure sensor to measure NNS. Data were acquired through the analog-digital converter of a microcontroller and transmitted via Bluetooth for real-time graphical analysis. Pilot testing was conducted with six hospitalized preterm newborns, measuring intensity, number of bursts, and sucks per burst. Results demonstrated that the system reliably captures both stages of NNS. Significance: This device provides an affordable, portable solution to support clinical decision-making in clinical units, facilitating accurate, objective monitoring of feeding readiness and developmental progression.

Indexed as

Sucking BehaviorEquipment DesignHumansInfant, NewbornSoftwareforce sensing resistorsnon-nutritive suckingpiezoresistive pressure sensors

Identifiers

PMID40871943
PMCPMC12389948

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.