Evidence map›Paper›PMID 40871900›Full record

ArticleSensors (Basel, Switzerland)2025

Validity of Body Composition Estimates in Women Assessed by a Multifrequency Bioelectrical Impedance Device.

Mitchell E Zaplatosch, Juliana F Meireles, Janeen S Amason, Sadaf Dabeer, Brian M Kliszczewicz, Gerald T Mangine, Valene G Barry, Barbara A Gower, Katherine H Ingram

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Observational
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mitchell E ZaplatoschDepartment of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA 30144, USA.ORCID 0000-0002-7031-6057
Juliana F MeirelesDepartment of Family and Community Medicine, School of Community Medicine, University of Oklahoma Health Sciences Center, Tulsa, OK 74135, USA.ORCID 0000-0001-8396-6449
Janeen S AmasonWellstar School of Nursing, Kennesaw State University, Kennesaw, GA 30144, USA.
Sadaf DabeerDivision of Endocrinology, Metabolism and Lipids, School of Medicine, Emory University, Atlanta, GA 30322, USA.ORCID 0000-0002-0564-4185
Brian M KliszczewiczDepartment of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA 30144, USA.ORCID 0000-0003-0692-3407
Gerald T MangineDepartment of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA 30144, USA.ORCID 0000-0003-2718-2564
Valene G BarryDepartment of Obstetrics and Gynecology, School of Medicine, Washington University in Saint Louis, St. Louis, MO 63110, USA.ORCID 0000-0003-2999-5948
Barbara A GowerDepartment of Nutrition Sciences, University of Alabama at Birmingham, Birmingham, AL 35233, USA.ORCID 0000-0001-8461-4613
Katherine H IngramDepartment of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA 30144, USA.ORCID 0000-0002-3052-9461

Funding

Why is the prevalence of obesity so high in U.S. Southern States? Regional predictors of BMI and obesity treatment response.P30DK056336 · NIDDK · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI James O Hill · 2000 to 2026
$31.9M
Kennesaw State University N/ANIDDK NIH HHS P30 DK056336
6 · The paper itself

Abstract

backgroundMultifrequency bioelectrical impedance devices such as the InBody 770 (IB770) offer faster measurements and lower costs compared with other body composition assessments. This study validated measures from IB770 against the deuterium oxide dilution technique (D2O) and DXA and compared a four-compartment (4C) model using total body water (TBW) derived from IB770 compared with D2O.

methodsA total of 55 adult females (mean ± SD, age: 21.1 ± 2.6 years) completed IB770 and DXA scans and the D2O protocol. Lin's concordance correlation coefficients (CCCs), Bland-Altman analyses, and other equivalence tests evaluated agreement between IB770 and the criterion for measures of fat mass (FM), fat-free mass (FFM), and TBW individually and as part of 4C models.

resultsThere was substantial agreement between IB770 and D2O for TBW (MD = Mean Difference) (MD = 0.34 L, CCC = 0.98) and between the IB770 and DXA for FM (MD = -0.22 kg, CCC = 0.99). IB770 overestimated FFM compared with DXA (MD = 3.15 kg, CCC = 0.91). Both 4C models had almost perfect agreement for FM (CCC = 0.99), FFM (CCC = 0.99), and body fat percentage (CCC = 0.99).

conclusionsIB770 is valid for assessing TBW and can be used within the context of a 4C model in females.

Indexed as

Body CompositionElectric ImpedanceAbsorptiometry, PhotonAdultBody WaterDeuterium OxideFemaleHumansYoung AdultDeuterium Oxide4-compartment modelbio-impedancebody compositionD2Ofat masslean masstotal body water

Identifiers

PMID40871900
PMCPMC12390487

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.