ArticleSensors (Basel, Switzerland)2025
Simulation-Rooted Assessment of Electromagnetic Calorimeters Based on Silicon Sensors.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
We present a Geant4-based simulation study of the electromagnetic sampling calorimeter (ECAL) foreseen in the LUXE experiment. The ECAL will enable precise measurement of the number and energy spectrum of positrons and electrons. The electromagnetic shower response, energy resolution, and linearity-properties that are essential for physics research-are studied. The Geant4 simulation model provides a good description of the data from the literature, and the stochastic energy resolution is comparable to the state-of-the-art resolution for a Si-W calorimeter. The simulated ECAL model consists of layers of solid-state sensors interspersed between tungsten plates, with the sensors divided into pads. The advantage of these detectors is their high active layer density, which facilitates the construction of more compact devices. A detailed description of the sensor response using MC simulations is fundamental to detector design and predicting energy measurement performance. We collected simulated data using electron beams in the energy range of 2 to 18 GeV, with a step of 2 GeV. The signal size distribution measured in the test beam campaign is well reproduced by the Geant4 simulation, confirming the accuracy of the simulation approach. The analysis described in this paper focuses on electromagnetic shower reconstruction and characterizes the ECAL response to electrons in terms of energy resolution and linearity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.