ArticleBioengineering (Basel, Switzerland)2025
Effect of Bone Quality, Implant Length, and Loading Timing on Stress Transmission in the Posterior Mandible: A Finite Element Analysis.
Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Article
- Biomechanical effect of implant thickness and screw diameter on CFR-PEEK subperiosteal implants: a three-dimensional finite element analysis.Scientific reports · 2026Article
- Finite Element Analysis of Peri-Implant Stress in Maxillary All-on-Four Rehabilitation: Effects of Posterior Implant Angulation and Loading Protocol.Materials (Basel, Switzerland) · 2026Article
- Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic Materials.Materials (Basel, Switzerland) · 2026Article
- Comparing the biological response to immediate versus delayed implants placement in terms of osseointegration and bone quality.Bioinformation · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
This study aimed to evaluate the biomechanical effects of implant length, mandibular morphology, graft application, loading timing, and force direction on peri-implant stress distribution using finite element analysis (FEA). Five mandibular models representing normal, atrophic, and graft-augmented conditions were constructed. Each model was analyzed with 6 mm and 12 mm Straumann Standard implants under two loading types, vertical (200 N) and oblique (100 N at 30°), across three loading protocols (immediate, early, and delayed). Stress analysis was conducted using von Mises and principal stress criteria, focusing on cortical and trabecular bone, the implant-abutment complex, and the mandibular canal. Under vertical loading, increasing the implant length from 6 mm to 12 mm reduced the maximum tensile stresses in trabecular bone from 0.930 MPa to 0.475 MPa (an approximate 49% decrease). However, oblique loading caused a substantial increase in stresses in all regions, with trabecular compressive stress reaching up to -19.102 MPa and cortical tensile stress up to 179.798 MPa in the atrophic mandible. Graft application significantly reduced peri-implant stresses; for example, maximum compressive stress in the cortical bone decreased from -227.051 MPa in the atrophic model to -13.395 MPa in the grafted model under similar loading conditions. Although the graft donor site was not explicitly modeled, the graft material (Bio-Oss) was anatomically positioned in the posterior mandible to simulate buccolingual augmentation and its biomechanical effects. Stress concentrations around the mandibular canal remained below the 6 MPa threshold for neurovascular injury in all scenarios, indicating a biomechanically safe outcome. These findings indicate that oblique loading and reduced bone volume may compromise implant survival, whereas graft application plays a critical role in mitigating stress levels and enhancing biomechanical stability. The study also emphasizes the importance of considering force direction and bone quality in clinical planning, and highlights the novelty of combining graft simulation with FEA to assess its protective role beyond implant length alone.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.