Evidence map›Paper›PMID 40868394›Full record

ArticleBioengineering (Basel, Switzerland)2025

Development of a Computationally Efficient CFD Method for Blood Flow Analysis Following Flow Diverter Stent Deployment and Its Application to Treatment Planning.

Soichiro Fujimura, Haruki Kanebayashi, Kostadin Karagiozov, Tohru Sano, Shunsuke Hataoka, Michiyasu Fuga, Issei Kan, Hiroyuki Takao, Toshihiro Ishibashi, Makoto Yamamoto and 1 more

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Soichiro FujimuraDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo 125-8585, Japan.
Haruki KanebayashiDivision of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Kostadin KaragiozovDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Tohru SanoDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Shunsuke HataokaDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Michiyasu FugaDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Issei KanDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.ORCID 0000-0003-4829-4784
Hiroyuki TakaoDivision of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Toshihiro IshibashiDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.
Makoto YamamotoDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo 125-8585, Japan.
Yuichi MurayamaDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo 105-8461, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intracranial aneurysms are a serious cerebrovascular condition with a risk of subarachnoid hemorrhage due to rupture, leading to high mortality and morbidity. Flow Diverter Stents (FDSs) have become an important endovascular treatment option for unruptured large or wide-neck aneurysms. Hemodynamic factors significantly influence treatment outcomes in aneurysms treated with FDSs, and Computational Fluid Dynamics (CFD) has been widely used to evaluate post-deployment flow characteristics. However, conventional wire-resolved CFD methods require extremely fine meshes to reconstruct individual FDS wires, resulting in prohibitively high computational costs. This severely limits their feasibility for use in clinical treatment planning, where fast and robust simulations are essential. To address this limitation, we developed a computationally efficient CFD method that incorporates a porous media model accounting for local variations in wire density after FDS deployment. Based on Virtual Stent Simulation, the FDS region was defined as a hollow cylindrical domain with spatially varying resistance derived from cell-specific wire density. We validated the proposed method using 15 clinical cases, demonstrating close agreement with conventional wire-resolved CFD results. Relative errors in key hemodynamic parameters, including velocity, shear rate, inflow rate, and turnover time, were within 5%, with correlation coefficients exceeding 0.98. The number of grid elements, the data size, and total analysis time were reduced by over 90%. The method also allowed comparison between Total-Filling (OKM Grade A) and Occlusion (Grade D) cases, and evaluation of different FDS sizing, positioning, and coil-assisted strategies. The proposed method enables practical and efficient CFD analysis following FDS treatment and supports hemodynamics-based treatment planning of aneurysms.

Indexed as

computational fluid dynamicsflow diverter stenthemodynamicsintracranial aneurysmporous media model

Identifiers

PMID40868394
PMCPMC12383731

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.