ArticleBioengineering (Basel, Switzerland)2025
Development of a Computationally Efficient CFD Method for Blood Flow Analysis Following Flow Diverter Stent Deployment and Its Application to Treatment Planning.
Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intracranial aneurysms are a serious cerebrovascular condition with a risk of subarachnoid hemorrhage due to rupture, leading to high mortality and morbidity. Flow Diverter Stents (FDSs) have become an important endovascular treatment option for unruptured large or wide-neck aneurysms. Hemodynamic factors significantly influence treatment outcomes in aneurysms treated with FDSs, and Computational Fluid Dynamics (CFD) has been widely used to evaluate post-deployment flow characteristics. However, conventional wire-resolved CFD methods require extremely fine meshes to reconstruct individual FDS wires, resulting in prohibitively high computational costs. This severely limits their feasibility for use in clinical treatment planning, where fast and robust simulations are essential. To address this limitation, we developed a computationally efficient CFD method that incorporates a porous media model accounting for local variations in wire density after FDS deployment. Based on Virtual Stent Simulation, the FDS region was defined as a hollow cylindrical domain with spatially varying resistance derived from cell-specific wire density. We validated the proposed method using 15 clinical cases, demonstrating close agreement with conventional wire-resolved CFD results. Relative errors in key hemodynamic parameters, including velocity, shear rate, inflow rate, and turnover time, were within 5%, with correlation coefficients exceeding 0.98. The number of grid elements, the data size, and total analysis time were reduced by over 90%. The method also allowed comparison between Total-Filling (OKM Grade A) and Occlusion (Grade D) cases, and evaluation of different FDS sizing, positioning, and coil-assisted strategies. The proposed method enables practical and efficient CFD analysis following FDS treatment and supports hemodynamics-based treatment planning of aneurysms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.