Evidence map›Paper›PMID 40864231›Full record

SynthesisSpine deformity2026

Internal mechanism failure of magnetic controlled growing rods (MCGRs) for early-onset scoliosis: a systematic review of implant retrieval analysis studies.

Riaz Mohammed, Pranav Shah, Bnar Massraf, Sashin Ahuja

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Spine deformity, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Riaz MohammedUniversity Hospital of Wales NHS Trust, Cardiff, UK.ORCID http://orcid.org/0000-0003-2334-3551
Pranav ShahUniversity Hospital of Wales NHS Trust, Cardiff, UK. dr.pranavshah07@gmail.com.ORCID http://orcid.org/0000-0003-1550-4888
Bnar MassrafCardiff University, Cardiff, UK.ORCID http://orcid.org/0009-0003-8232-522X
Sashin AhujaUniversity Hospital of Wales NHS Trust, Cardiff, UK.ORCID http://orcid.org/0000-0001-8676-6100

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMagnetic controlled growing rods (MCGRs) are used to treat early-onset scoliosis when nonsurgical options fail, controlling curve progression and allowing for continued spinal growth. Recent reports of unplanned reoperations and mechanical failure of MCGRs have led to further research. This is a systematic review on the retrieval analysis of explanted MCGR rods. Understanding the failure mechanisms will shed light on the survivorship and complications associated with the implant.

methodsA Medline and EMBASE database search was performed, looking at all variations in the terms "magnetic controlled growing rods" and the terms "retrieval/explant/metallosis" All published retrieval analysis studies of MCGR were included, and all clinical outcome studies, biomechanical testing studies, review articles, and case reports were excluded. Data were collected regarding the source, year, and aim of the study; number of patients and rods analysed; duration of implantation; and main findings and conclusions.

resultsNine studies (454 rods) reported metallosis due to O-ring damage (67%), internal mechanism failure of locking pins (45%) and rod fracture (7%) in all MCGR generations. Actuator locking pin fractures reported in 174 rods (38.3%) continue to persist despite newer implant iterations. The pin fracture rates decreased from 52% in MAGEC 1.3 to 15% in MAGEC X.

conclusionsMCGR failure is multifactorial, and metallosis is of significant concern because of the unknown long-term effects in patients. Early recognition and revision of existing rods in situ is essential, along with continued efforts to reduce mechanical failure in future iterations of MAGEC. LEVELS OF EVIDENCE: MCGR failure is multifactorial, and metallosis is of significant concern because of the unknown long-term effects in patients. Early recognition and revision of existing rods in situ is essential, along with continued efforts to reduce mechanical failure in future iterations of MAGEC. This systematic review provides Level III evidence on failure mechanisms in MCGR, as the results were obtained from Level III studies. The levels of evidence for all relevant references can be found in the reference section. LEVEL II: [1-4]. LEVEL III: [5-34]. LEVEL IV: [35-44]. LEVEL V: [45-50].

Indexed as

Internal FixatorsProsthesis FailureScoliosisAge of OnsetChildHumansReoperationEOSMAGECMCGRMetallosisRetrieval

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.