Evidence map›Paper›PMID 40863895›Full record

ArticleToxics2025

The Genotoxic Potential of Organic Emissions from Domestic Boilers Combusting Biomass and Fossil Fuels.

Jitka Sikorova, Frantisek Hopan, Lenka Kubonova, Jiri Horak, Alena Milcova, Pavel Rossner, Antonin Ambroz, Kamil Krpec, Oleksandr Molchanov, Tana Zavodna

Abstract read
In one paragraph

Article in Toxics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jitka SikorovaDepartment of Toxicology and Molecular Epidemiology, Institute of Experimental Medicine of the CAS, Videnska 1083, 142 00 Prague, Czech Republic.ORCID 0000-0002-6143-0229
Frantisek HopanCentre for Energy and Environmental Technologies, Energy Research Centre, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0002-8248-2167
Lenka KubonovaCentre for Energy and Environmental Technologies, Energy Research Centre, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0003-3256-8373
Jiri HorakCentre for Energy and Environmental Technologies, Energy Research Centre, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0001-6665-5294
Alena MilcovaDepartment of Toxicology and Molecular Epidemiology, Institute of Experimental Medicine of the CAS, Videnska 1083, 142 00 Prague, Czech Republic.
Pavel RossnerDepartment of Toxicology and Molecular Epidemiology, Institute of Experimental Medicine of the CAS, Videnska 1083, 142 00 Prague, Czech Republic.ORCID 0000-0001-6921-5446
Antonin AmbrozDepartment of Toxicology and Molecular Epidemiology, Institute of Experimental Medicine of the CAS, Videnska 1083, 142 00 Prague, Czech Republic.ORCID 0000-0002-3265-5744
Kamil KrpecCentre for Energy and Environmental Technologies, Energy Research Centre, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic.
Oleksandr MolchanovCentre for Energy and Environmental Technologies, Energy Research Centre, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0002-7635-3115
Tana ZavodnaDepartment of Toxicology and Molecular Epidemiology, Institute of Experimental Medicine of the CAS, Videnska 1083, 142 00 Prague, Czech Republic.ORCID 0000-0002-1482-9341

Funding

European Regional Development Fund CZ.02.1.01/0.0/0.0/16_019/0000798European Structural and Investments Funds in the frame of Operational Programme Research Development and Education CZ.02.1.01/0.0/0.0/18_046/0015586Ministry of Education Youth and Sports LM2023053Ministry of Education Youth and Sports LM2023066Technology Agency of the Czech Republic SS02030031
6 · The paper itself

Abstract

Solid fuels are still widely used in household heating in Europe and North America. Emissions from boilers are released in proximity to people. Therefore, there is a need to minimise the toxicity of emissions affecting human health to the greatest extent possible. This study compares the genotoxic potential of the emissions of four boilers of modern and old design (automatic, gasification, down-draft, over-fire) operating at reduced output to simulate the real-life combustion fed by various fossil and renewable solid fuels (hard coal, brown coal, brown coal briquettes, wood pellets, wet and dry spruce). Organic emissions were tested for genotoxic potential by analysing bulky DNA adducts and 8-oxo-dG adduct induction. There was no consistent genotoxic pattern among the fuels used within the boilers. Genotoxicity was strongly correlated with polycyclic aromatic hydrocarbon (PAH) content, and even stronger correlation was observed with particulate matter (PM). In all measured variables (PM, PAHs, genotoxicity), the technology of the boilers was a more important factor in determining the genotoxic potential than the fuels burned. The highest levels of both bulky and 8-oxo-dG DNA adducts were induced by organics originating from the over-fire boiler, while the automatic boiler exhibited genotoxic potential that was ~1000- and 100-fold lower, respectively.

Indexed as

8-oxo-dGDNA adductsdomestic heatinggenotoxicityparticulate matterpolycyclic aromatic hydrocarbons