Evidence map›Paper›PMID 40863884›Full record

ArticleTomography (Ann Arbor, Mich.)2025

Contrast-Enhanced Mammography in Breast Lesion Assessment: Accuracy and Surgical Impact.

Graziella Di Grezia, Sara Mercogliano, Luca Marinelli, Antonio Nazzaro, Alessandro Galiano, Elisa Cisternino, Gianluca Gatta, Vincenzo Cuccurullo, Mariano Scaglione

Abstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Graziella Di GreziaDepartment of Life Sciences, Health and Healthcare Professions Link Campus University, 00165 Rome, Italy.ORCID 0000-0003-4507-3505
Sara MercoglianoBreast Unit, Radiology and Diagnostic Imaging Department, AORN Santi Anna e Sebastiano, 81100 Caserta, Italy.
Luca MarinelliDiagnostic Imaging, University of Campania Luigi Vanvitelli, 80138 Naples, Italy.
Antonio NazzaroIndependent Researcher, 83100 Avellino, Italy.ORCID 0009-0001-1463-8940
Alessandro GalianoDepartment of Radiology, P.O. A. Perrino Hospital, 72100 Brindisi, Italy.
Elisa CisterninoDepartment of Radiology, P.O. A. Perrino Hospital, 72100 Brindisi, Italy.ORCID 0009-0004-3657-5364
Gianluca GattaDepartment of Advanced Medical and Surgical Sciences, University of Campania Luigi Vanvitelli, 80138 Naples, Italy.ORCID 0000-0003-0874-8294
Vincenzo CuccurulloDepartment of Precision Medicine, University of Campania Luigi Vanvitelli, 80138 Naples, Italy.ORCID 0000-0003-0474-7163
Mariano ScaglioneDepartment of Radiology, University of Sassari, 07100 Sassari, Italy.ORCID 0000-0002-0910-8064

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate preoperative tumor sizing is critical for optimal surgical planning in breast cancer. Contrast-enhanced mammography (CEM) has emerged as a promising modality, yet its accuracy relative to conventional imaging and pathology requires further validation.

objectiveTo prospectively evaluate the dimensional accuracy and reproducibility of CEM compared to mammography and ultrasound, using surgical pathology as the reference standard.

methodsA total of 205 patients with 267 breast lesions underwent preoperative CEM, mammography, and ultrasound. Tumor sizes were measured independently by two radiologists. Accuracy was assessed via mean absolute error (MAE), Pearson and Spearman correlations, and inter-reader agreement evaluated by intraclass correlation coefficient (ICC) and Gwet's AC1. Sensitivity analyses included bootstrap confidence intervals and log-transformed data. The surgical impact of additional lesions detected by CEM was also analyzed.

resultsCEM showed superior accuracy with a mean absolute error of 0.46 mm (95% CI: 0.24-0.68) compared to mammography (4.06 mm) and ultrasound (3.52 mm) (

conclusionsCEM provides highly accurate and reproducible tumor size estimation superior to conventional imaging modalities, with potential clinical impact through detection of additional lesions. Its ability to detect additional lesions not seen on mammography or ultrasound has direct implications for surgical decision making, with the potential to reduce reoperations and improve oncologic and cosmetic outcomes. However, high correlation values and selective patient cohorts warrant cautious interpretation. Further multicenter studies are needed to confirm these findings and define CEM's role in clinical practice.

Indexed as

Breast NeoplasmsContrast MediaMammographyAdultAgedAged, 80 and overBreastFemaleHumansMiddle AgedProspective StudiesReproducibility of ResultsSensitivity and SpecificityTumor BurdenUltrasonography, MammaryContrast Mediabreast cancerbreast imagingcontrast enhanced mammographymammographyultrasound

Identifiers

PMID40863884
PMCPMC12389778

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.