ArticleBiosensors2025
Non-Enzymatic Selective Detection of Histamine in Fishery Product Samples on Boron-Doped Diamond Electrodes.
Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Integration of freshness monitoring and active packaging technologies for aquatic products.Journal of food and drug analysis · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Histamine sensing that uses enzymatic reactions is the most common form of testing due to its selectivity for histamine. However, enzymes are difficult to store for long periods of time, and the inactivation of enzymes decreases the reliability of the results. In this study, we developed a novel, quick, and easily operated histamine sensing technique that takes advantage of the histamine redox reaction and does not require enzyme-based processes. Because the redox potential of histamine is relatively high, we used a boron-doped diamond (BDD) electrode that has a wide potential window. At pH 8.4, which is between the acidity constant of histamine and the isoelectric point of histidine, it was found that an oxygen-terminated BDD surface successfully detected histamine, both selectively and exclusively. Measurements of the sensor's responses to extracts from fish meat samples that contained histamine at various concentrations revealed that the sensor responds linearly to the histamine concentration, thus allowing it to be used as a calibration curve. The sensor was used to measure histamine in another fish meat sample treated as an unknown sample, and the response was fitted to the calibration curve to perform an inverse estimation. When estimated in this way, the histamine concentration matched the certified value within the range of error. A more detailed examination showed that the sensor response was little affected by the histidine concentration in the sample. The detection limit was 20.9 ppm, and the linear response range was 0-150 ppm. This confirms that this sensing method can be used to measure standard histamine concentrations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.