ArticleBiomimetics (Basel, Switzerland)2025

The Effect of Different Tightening Torques of Implant Cone Morse Abutment Connection Under Dynamic Fatigue Loading: An In Vitro Study.

Felice Lorusso, Antonio Scarano, Sergio Rexhep Tari, Ishita Singhal, Funda Goker, Maria Costanza Soldini, Gianluca Martino Tartaglia, Massimo Del Fabbro

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Felice LorussoDepartment of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0002-2660-9231
Antonio ScaranoDepartment of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0003-1374-6146
Sergio Rexhep TariDepartment of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0009-0000-4922-8557
Ishita SinghalDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, via Della Commenda 10, 20122 Milano, Italy.ORCID 0000-0002-5501-4720
Funda GokerDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, via Della Commenda 10, 20122 Milano, Italy.ORCID 0000-0002-2354-361X
Maria Costanza SoldiniDepartment of Periodontology, Universitat Internacional de Catalunya, 08195 Barcelona, Spain.ORCID 0000-0003-0826-8901
Gianluca Martino TartagliaDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, via Della Commenda 10, 20122 Milano, Italy.
Massimo Del FabbroDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, via Della Commenda 10, 20122 Milano, Italy.ORCID 0000-0001-7144-0984

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe implant-abutment joint is important for the long-term marginal tissue integrity in terms of biomimetic design that replicates the natural dentition under mastication forces. This study aimed to evaluate conical implant-abutment joints coupled at different tightening torque values through a mechanical fatigue test.

methodsEighty conic implants (Ø: 3.8 mm L: 10 mm) with a 6° cone morse joint were embedded in resin blocks with an inclination of 30° ± 2°. The samples were divided into 8 groups (4 Test and 4 Control). The implant-abutment joints were coupled with different tightening torques: 25 Ncm (Group I), 30 Ncm (Group II), 35 Ncm (Group III) and 40 Ncm (Group IV). An in vitro cyclic loading test (1 × 10

resultsMicroscopy observation results showed significant differences among torque groups. We found that 30 Ncm had the best stability with less microgap.

conclusionsTightening torque plays an important role in the distortion of the cone morse joint under mechanical forces. However, further studies should be conducted to validate the results using different implant-abutment joints for comparison.

Indexed as

abutment interfacecone morse connectiondental implantdental implant–abutment connectiondental implant loadingfatigue performance

Identifiers

PMID40862884
PMCPMC12383328

What OpenQuestion holds

Textmetadata
LicenceCC BY