Evidence map›Paper›PMID 40861008›Full record

ArticleFrontiers in rehabilitation sciences2025

Development and validation of a sliding type continuous passive motion automation device for evaluation and rehabilitation of frozen shoulder: a pilot study.

Jewoo Lee, Sung-Sik Yun, Kyung Rok Oh, Sun Gun Chung, Wonjae Hwang, Keewon Kim, Kyu-Jin Cho

Erratum issuedAbstract read
In one paragraph

Article in Frontiers in rehabilitation sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Jewoo LeeDepartment of Mechanical Engineering, Seoul National University, Seoul, Republic of Korea.
Sung-Sik YunDepartment of Mechanical Engineering, Seoul National University, Seoul, Republic of Korea.
Kyung Rok OhDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Sun Gun ChungDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Wonjae HwangDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Keewon KimDepartment of Rehabilitation Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Kyu-Jin ChoDepartment of Mechanical Engineering, Seoul National University, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Frozen shoulder (FS) is a condition that results in pain and restricted range of motion (ROM) in the shoulder joint, impacting daily activities. Current rehabilitation methods, including physical therapy and passive range of motion (PROM) exercise, can be limited by cost and availability. This study aimed to develop and test a novel robotic CPM device capable of measuring joint stiffness and improving accessibility and self-exercise effectiveness for FS patients. Methods: A 3-armed randomized clinical trial was conducted with 12 FS patients allocated into three groups: (1) hot pack treatment (negative control), (2) PROM by physiotherapists (active control), and (3) robotic CPM device-assisted exercise (intervention). ROM, pain levels using the Visual Analogue Scale (VAS), and the Shoulder Pain and Disability Index (SPADI) were measured at baseline, immediately post-intervention, and after a 6-week follow-up. A linear mixed model was applied for inter-group and intra-group analyses. Torque and stiffness were calculated using sensor data collected by the robotic device and Inertial Measurement Units (IMUs) for precise monitoring. Results: The intervention group showed significant improvement in ROM compared to the negative control group, particularly in external rotation (p = 0.022). Intra-group analysis for the intervention group revealed average ROM increases of Conclusions: The developed robotic CPM device demonstrated potential in improving ROM and reducing passive stiffness in FS patients, showing comparable results to therapist-assisted exercise. While the device enhances accessibility and self-monitoring capabilities, further studies are required to validate its use in home settings and assess its impact on long-term motivation for self-exercise. Clinical Trial Registration: The clinical trial was approved and registered under Seoul National University Hospital Institutional Review Board (IRB No. 2206-161-1335).

Indexed as

continuous passive motion (CPM)frozen shoulderjoint stiffnessrehabilitationrobot

Identifiers

PMID40861008
PMCPMC12375683

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.