Evidence map›Paper›PMID 40859284›Full record

ArticleWorld journal of emergency surgery : WJES2025

Variation and accuracy of intra-abdominal pressure measurement in different body positions: a prospective study.

Salar Tayebi, Robert Wise, Prashant Nasa, Luca Malbrain, Johan Stiens, Wojciech Dabrowski, Manu L N G Malbrain

Abstract read
In one paragraph

Article in World journal of emergency surgery : WJES, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Salar TayebiDepartment of Electronics and Informatics, Vrije Universiteit Brussel, Brussels, 1050, Belgium.ORCID http://orcid.org/0000-0001-6751-1858
Robert WiseAdult Intensive Care, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, OX3 9DU, UK.
Prashant NasaDepartment of Critical Care Medicine and Anaesthesia, New Cross Hospital, The Royal Wolverhampton NHS Trust, Wolverhampton, UK.
Luca MalbrainMaster of Medicine in Family Medicine, Katholieke Universiteit Leuven, Leuven, 3000, Belgium.
Johan StiensDepartment of Electronics and Informatics, Vrije Universiteit Brussel, Brussels, 1050, Belgium.
Wojciech DabrowskiFirst Department of Anaesthesiology, Intensive Therapy, Medical University of Lublin, Lublin, Poland.
Manu L N G MalbrainFirst Department of Anaesthesiology, Intensive Therapy, Medical University of Lublin, Lublin, Poland. manu.malbrain@telenet.be.ORCID http://orcid.org/0000-0002-1816-5255

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecent studies confirm that intra-abdominal hypertension (IAH) frequently develops in critically ill patients, posing a significant risk of organ failure and increased mortality. Accurate intra-abdominal pressure (IAP) measurement is essential for effective diagnosis, prevention, and treatment. Previous studies indicate that accurate IAP measurement using traditional Foley catheters requires the bladder to be filled with a maximum of 25 mL of sterile saline solution after clamping the catheter, restricting the ability to monitor IAP continuously due to variations in the bladder fill volume. The TraumaGuard catheter enables continuous IAP measurement irrespective of bladder fill volume.

objectiveThe primary objective was the validation of the TraumaGuard catheter (Sentinel Medical Technologies, Jacksonville, Florida, USA), a new continuous bladder pressure monitoring device. ICU patients were studied across different body positions to assess measurement accuracy by comparing the correlation, bias, precision, and agreement between IAP readings obtained using the TraumaGuard catheter and the FoleyManometer measurement method (SecurMeter, Deltamed, Viadana, Italy), which serves as the gold standard. The secondary endpoint of this study was to investigate the impact of different body positions on IAP.

methodsAdult ICU patients (≥ 18 years) requiring bladder catheterisation were enrolled. IAP was measured using a TraumaGuard catheter (IAPTG) and FoleyManometer method (IAPFM) across multiple positions to have a broad range of IAP values and to study the impact of body position on IAP measurement. Pairwise analysis of IAPTG and IAPFM in the supine, reverse Trendelenburg (15°, 30°, and 45°), and head-of-bed (HOB) elevation positions (15°, 30°, and 45°) was performed using correlation, concordance, and Bland-Altman analyses. The error-grid analysis assessed the risk associated with inaccurate measurements at each body position. The robustness of the TraumaGuard catheter as a detection system for IAH detection system was evaluated by receiver operating characteristic (ROC) curve. The IAP variation as a function of body position was investigated and compared with the reviewed literature. Gender, age, body mass index (BMI), and sequential organ failure assessment (SOFA) score were also recorded for each participant.

resultsTwenty-five adult ICU patients with a mean age of 63.6 ± 11.6 years and BMI of 28.3 ± 3.7 kg/m2 were included. The mean IAP increased from 9.8 ± 1.7 mmHg in supine to 10.4 ± 1.5 mmHg in reverse Trendelenburg and 14.9 ± 1.6 mmHg in HOB elevation positions. The correlation coefficients were 0.9, 0.9, and 0.8 for supine, reverse Trendelenburg, and HOB elevation positions. The supine positions showed a bias and precision of 0.8 and 1.7 mmHg according to Bland-Altman analysis. Reverse Trendelenburg and HOB elevation positions showed a bias of − 0.3 and 1.5 mmHg with a precision of 1.5 and 1.6 mmHg, respectively. The lower and upper limits of agreement were − 2.5–4.2 mmHg, − 3.2–2.6 mmHg, and − 1.6–4.6 mmHg for supine, reverse Trendelenburg, and HOB elevation positions with a percentage error of 35%, 28%, and 21%, respectively. Concordance coefficients were highest in reverse Trendelenburg positions (100.0%) compared to supine (95.3%) and HOB elevation (92.1%) positions. The error-grid analysis indicated no medium/high-risk errors for supine and reverse Trendelenburg and a 2.7% medium-risk error at HOB elevation positions.

conclusionThe results of this validation of a new continuous IAP monitoring device in ICU patients showed excellent results when compared to the gold standard. Changing the body position from supine to reverse Trendelenburg or HOB elevation increases the IAP.

Indexed as

Intra-Abdominal HypertensionPatient PositioningPostureAgedFemaleHumansIntensive Care UnitsMaleMiddle AgedMonitoring, PhysiologicPressureProspective StudiesReproducibility of ResultsBody positionHead-of-bedIntra-abdominal pressureLateralProneReverse trendelenburgSemi-recumbentSupine

Identifiers

PMID40859284
PMCPMC12382104

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.