Effect of connector size and configuration on the fracture resistance of a long-span implant-supported monolithic zirconia fixed partial denture (An in vitro Study).

Alaa M Khorshed, Lomaya Ghanem, Tamer E Shokry

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Alaa M KhorshedFaculty of oral and Dental Medicine, Misr International University, Cairo, Egypt.
Lomaya GhanemConservative Dentistry Department, Faculty of oral and dental Medicine, Misr International university, Cairo, Egypt.
Tamer E ShokryFixed prosthodontics Department, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt. tamershokry.209@azhar.edu.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMonolithic zirconia fixed partial dentures (FPDs) have gained popularity due to their high strength, biocompatibility and reduced veneer chipping compared to bilayered restorations. However, the connector region remains a critical point of mechanical failure, especially in long span implant supported FPDs subjected to high masticatory forces. The purpose of this in vitro study was to compare the fracture resistance of implant-supported Y-TZP (yttria-stabilized tetragonal zirconia polycrystal) fixed partial dentures (FPDs) with two connector sizes (9 mm² and 12 mm²) and two connector cross-sectional shapes (oval and circular).

methodsTwenty-eight four-unit posterior implant-supported monolithic zirconia FPDs were fabricated. They were divided into two equal groups (n = 14) based on connector cross-sectional shape (oval vs. circular), each further subdivided by connector size (9 mm² or 12 mm², n = 7 per subgroup). A static fracture test was performed by applying an occlusal load at a crosshead speed of 1 mm/min until failure, and the fracture resistance (load to fracture) was recorded. The data distribution was first checked with the Kolmogorov-Smirnov and Shapiro-Wilk tests, which confirmed that the fracture resistance values followed a normal (parametric) distribution. A two-way analysis of variance (ANOVA) was performed to assess the effects of the connector size (9 mm² vs. 12 mm²), connector cross-section (oval vs. circular), and their interaction on the mean fracture resistance. The significance level was set at α = 0.05.

resultsRegardless of cross-sectional shape, the 9 mm² connector groups showed significantly lower mean fracture resistance than the 12 mm² connector groups. Regardless of connector size, the oval cross-section groups showed significantly higher mean fracture resistance than the circular groups.

conclusionBased on the findings of this in vitro study, it can be concluded that increasing the connector cross-sectional area and using an oval connector shape both enhance the fracture resistance of long-span monolithic zirconia FPDs.

Indexed as

Dental MaterialsDental Prosthesis, Implant-SupportedDental Restoration FailureDenture DesignDenture, Partial, FixedZirconiumBite ForceDental Stress AnalysisHumansMaterials TestingStress, MechanicalSurface PropertiesYttriumDental Materialsyttria stabilized tetragonal zirconiaYttriumZirconiumzirconium oxideConnector designConnector sizeFixed partial dentureFracture resistanceMonolithic zirconia