Evidence map›Paper›PMID 40858729›Full record

ArticleScientific reports2025

Improved pulmonary embolism detection in CT pulmonary angiogram scans with hybrid vision transformers and deep learning techniques.

Abeer Abdelhamid, Amir El-Ghamry, Ehab H Abdelhay, Mohammed M Abo-Zahhad, Hossam El-Din Moustafa

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abeer AbdelhamidElectronics and Communications Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt. abeerabdo37@std.mans.edu.eg.
Amir El-GhamryComputer Science Department, Faculty of Computers and Information, Mansoura University, Mansoura, 35516, Egypt.
Ehab H AbdelhayElectronics and Communications Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt.
Mohammed M Abo-ZahhadElectrical Engineering Department, Faculty of Engineering, Sohag University, Sohag, 82524, Egypt.
Hossam El-Din MoustafaElectronics and Communications Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, 35516, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pulmonary embolism (PE) represents a severe, life-threatening cardiovascular condition and is notably the third leading cause of cardiovascular mortality, after myocardial infarction and stroke. This pathology occurs when blood clots obstruct the pulmonary arteries, impeding blood flow and oxygen exchange in the lungs. Prompt and accurate detection of PE is critical for appropriate clinical decision-making and patient survival. The complexity involved in interpreting medical images can often results misdiagnosis. However, recent advances in Deep Learning (DL) have substantially improved the capabilities of Computer-Aided Diagnosis (CAD) systems. Despite these advancements, existing single-model DL methods are limited when handling complex, diverse, and imbalanced medical imaging datasets. Addressing this gap, our research proposes an ensemble framework for classifying PE, capitalizing on the unique capabilities of ResNet50, DenseNet121, and Swin Transformer models. This ensemble method harnesses the complementary strengths of convolutional neural networks (CNNs) and vision transformers (ViTs), leading to improved prediction accuracy and model robustness. The proposed methodology includes a sophisticated preprocessing pipeline leveraging autoencoder (AE)-based dimensionality reduction, data augmentation to avoid overfitting, discrete wavelet transform (DWT) for multiscale feature extraction, and Sobel filtering for effective edge detection and noise reduction. The proposed model was rigorously evaluated using the public Radiological Society of North America (RSNA-STR) PE dataset, demonstrating remarkable performance metrics of 97.80% accuracy and a 0.99 for Area Under Receiver Operating Curve (AUROC). Comparative analysis demonstrated superior performance over state-of-the-art pre-trained models and recent ViT-based approaches, highlighting our method's effectiveness in improving early PE detection and providing robust support for clinical decision-making.

Indexed as

Computed Tomography AngiographyDeep LearningPulmonary EmbolismDiagnosis, Computer-AssistedHumansNeural Networks, ComputerPulmonary ArteryROC CurveComputed Tomography (CT)Deep Learning (DL)Discrete Wavelet Transforms (DWT)Pulmonary Embolism (PE)Vision Transformers (ViT)

Identifiers

PMID40858729
PMCPMC12381140

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.