Evidence map›Paper›PMID 40857524›Full record

ArticleAdvanced nanobiomed research2025

Long-Term Neural Recording Performance of PEDOT/CNT/Dexamethasone Coated Electrode Array Implanted in Visual Cortex of Rats.

Asiyeh Golabchi, Bingchen Wu, Zhanhong Jeff Du, Xinyan Tracy Cui

Abstract read
In one paragraph

Article in Advanced nanobiomed research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Review
  6. In vivo microelectrode arrays for neuroscience.Nature reviews. Methods primers · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Asiyeh GolabchiDepartment of Bioengineering, University of Pittsburgh, 5056 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA 15213, USA.
Bingchen WuDepartment of Bioengineering, University of Pittsburgh, 5056 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA 15213, USA.
Zhanhong Jeff DuDepartment of Bioengineering, University of Pittsburgh, 5056 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA 15213, USA.
Xinyan Tracy CuiDepartment of Bioengineering, University of Pittsburgh, 5056 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA 15213, USA.

Funding

Efficiency and Safety of Microstimulation Via Different Electrode MaterialsR01NS110564 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2019 to 2024
$3.1M
Investigation of Cognitive and Affective Deficits Post TBI Using Multimodal Flexible Neural ProbesR01NS136622 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI XINYAN Tracy CUI, AMY K WAGNER · 2024 to 2026
$1.6M
NINDS NIH HHS R01 NS110564NINDS NIH HHS R01 NS136622
6 · The paper itself

Abstract

Implantable neural electrode arrays can be inserted in the brain to provide single-cell electrophysiology recording for neuroscience research and brain-machine interface applications. However, maintaining signal quality over time is complicated by inflammatory tissue responses and degradation of electrode materials. Organic electrode coatings offer a solution by enhancing recording and stimulation capabilities, including reduced impedance, increased charge injection capacity, and the ability to incorporate and release anti-inflammatory drugs. In this study, acid-functionalized multi-walled carbon nanotubes (CNTs) loaded with dexamethasone (Dex) were incorporated into poly (3,4-ethylendioxythiophene) (PEDOT) as electrode coatings. We investigated the electrochemical stability and recording performance of the PEDOT/CNT/Dex coating over an extended period of approximately 18 months. Cyclic voltammetric (CV) stimulation was used to trigger Dex release in half of the recording sites during the first 11 days of implantation to reduce the acute inflammation. The PEDOT/CNT/Dex coated floating microelectrode arrays demonstrated stable in vivo electrode impedance and successful detection of visually evoked neural activity from the rat visual cortex even at chronic time points. Additionally, the CV-stimulated sites exhibited higher single-unit recording yield, amplitudes, and signal-to-noise ratio compared to unstimulated sites. These results highlight the potential of anti-inflammatory treatments to improve the quality and longevity of chronic neural recordings.

Identifiers

PMID40857524
PMCPMC12352372

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked