SynthesisLasers in surgery and medicine2025
Laser Versus Cold Steel Dissection Tonsillectomy in Recurrent Acute Tonsillitis: A Systematic Review and Meta-Analysis.
Synthesis in Lasers in surgery and medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
objectivesSevere recurrent acute tonsillitis (RAT) is commonly treated by removing the palatine tonsils, namely tonsillectomy (TE). Laser TE has been suggested as an alternative to cold steel dissection, although its efficacy and safety for the surgical treatment of RAT remain unclear. Therefore, we conducted a systematic review and meta-analysis comparing laser TE to cold steel dissection TE in patients with RAT.
methodsWe systematically searched PubMed, Embase, and Cochrane Central for eligible studies. Outcomes of interest were intraoperative blood loss, operation time, quality of life, postoperative pain, and postoperative hemorrhage. Subgroup and sensitivity analyses were performed. RStudio v4.1.0 and Review Manager v5.4 were used for statistical analysis. A prospective protocol was registered in PROSPERO (CRD42024533742).
resultsNine studies, including six randomized trials, met eligibility criteria, comprising 612 patients with RAT. In total, 1224 tonsils were excised; 612 (50%) were submitted to laser TE, and the remaining to cold steel dissection. Laser was associated with lower intraoperative blood loss (mean difference [MD] -35.89; 95% confidence interval [CI] [-53.08, -18.71]; p < 0.01; I² = 100%) and operation time (MD -10.46; 95% CI [-16.63, -4.29]; p < 0.01; I² = 99%). No significant differences between interventions were found in postoperative pain, quality of life, or postoperative hemorrhage.
conclusionsIn patients with RAT, laser TE yielded reduced intraoperative blood loss and operation time, with comparable hemorrhage risk, postoperative pain, and quality of life to cold steel dissection. Yet, the occurrence of post-surgery sore throat remains uncertain, highlighting the need for further randomized trials reporting long-term outcomes after tonsil surgery.