ArticleEndocrine, metabolic & immune disorders drug targets2026
Continuous Interstitial Glucose Monitoring through a Long-Term Subcutaneous Implantable Sensor during Pregnancy in Type 1 Diabetes: A Two- Patient Case Report.
Article in Endocrine, metabolic & immune disorders drug targets, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionOptimal glycaemic control is crucial during pregnancy in women with type 1 diabetes mellitus (T1D). Current guidelines, based on positive data from the CONCEPTT (Continuous Glucose Monitoring in Pregnant Women With Type 1 Diabetes Trial), on maternal glycaemic control and fetal outcomes, recommend offering real-time Continuous Glucose Monitoring (rt-CGM) as a standard method in all pregnancies of women with type 1 diabetes (T1D). CASE PRESENTATION: In these two clinical cases, we describe for the first time the gestational outcomes in two patients with T1D who chose to maintain a long-term implantable subcutaneous sensor (Eversense XL®) as a CGM method during their pregnancies. The first case concerns a 33- year-old young woman with a 25-year history of T1D on Continuous Subcutaneous Insulin Infusion (CSII), who faced her first pregnancy with a suboptimal preconception glycaemic control; the second case describes the second pregnancy of a 37-year-old patient with a more recently diagnosed T1D, on multiple daily injection (MDI) therapy who achieved adequate glycaemic compensation before planned conception.
conclusionThe subcutaneous sensor replacement was carried out at the beginning and end of the 2