Evidence map›Paper›PMID 40849574›Full record

ArticleScientific reports2025

Design and control of a permanent magnet-based robotic system for navigating tetherless magnetic devices in viscous environments.

Zhengya Zhang, Anke Klingner, Sarthak Misra, Islam S M Khalil

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zhengya ZhangDepartment of Biomaterials & Biomedical Technology, University of Groningen and University Medical Center Groningen, Groningen, 9713 AV, The Netherlands.
Anke KlingnerDepartment of Physics, The German University in Cairo, Cairo, Egypt.
Sarthak MisraDepartment of Biomaterials & Biomedical Technology, University of Groningen and University Medical Center Groningen, Groningen, 9713 AV, The Netherlands.
Islam S M KhalilRobotics and Mechatronics Research Group, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, 7500 AE, The Netherlands. i.s.m.khalil@utwente.nl.

Funding

project-MAESTRO 866494
6 · The paper itself

Abstract

Tetherless magnetic devices (TMDs) that are driven using external stimuli have potential applications in minimally invasive surgery. The magnetic field produced by electromagnet- and permanent magnet-based robotic systems is a viable option as an external stimulus to enable the motion of a TMD in viscous and viscoelastic media. In order to realize the navigation of TMDs in fluidic environments, we design a permanent magnet-based robotic system with an open configuration using two synchronized rotating magnetic dipoles to generate time-varying rotating magnetic fields. These fields are used to apply torque on a TMD in low-Reynolds-number flow regimes. The configuration of the system is vertically symmetric, allowing permanent magnets to exert relatively uniform magnetic fields within the center of the workspace. We derive the configuration-to-pose kinematics and the pose-to-field mapping of the system. Such derivation is the basis for realizing the motion control of TMDs in three-dimensional space. The kinematic system holds one translational degree of freedom (DOF) and three rotational DOFs, allowing it to control the pose of actuator magnets with four DOFs. The nonlinear inverse kinematic problem is solved using an optimization algorithm. The experimental results of this level of control demonstrate that the mean absolute error and the maximum tracking error of three-dimensional motion control are 1.18 mm and 2.64 mm, respectively. This paper tackles the challenge of generating and controlling synchronized rotating magnetic fields to actuate and navigate TMDs. Commonly, this involves collaboratively manipulating two permanent magnets by attaching each to the end-effector of an industrial robot. This paper proposes a novel approach: robotically manipulating two permanent magnets through a symmetric configuration constrained by a connecting plate. This method simplifies the manipulation of rotating magnetic fields, thereby aiding the simplification of TMD motion control strategies. Future research will improve the design of this robotic system to offer more degrees of freedom, thus achieving greater flexibility in TMD motion control.

Indexed as

Kinematics-analysisMotion controlPermanent magnetRotating fieldSynchronizationTetherless magnetic deviceUntethered

Identifiers

PMID40849574
PMCPMC12375033

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.