ArticleInternational journal of implant dentistry2025
Influence of implant macrodesign and insertion load during implant placement on primary stability in artificial bone.
Article in International journal of implant dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Insertion Torque Characteristics of the KS 3 Implant in Weak Bone, Standardized Extraction-Socket-like, and Maxillary Sinus Simulation Models: An In Vitro Comparative Study.Bioengineering (Basel, Switzerland) · 2026Article
- In vitro evaluation of different implant systems and their influence on primary stability.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundImplant placement is a critical step for achieving primary stability. During this process, a compressive force, referred to as an "insertion load," is applied through a handpiece or manual driver. However, the influence of the insertion load has not been quantitatively investigated. Since primary stability is essential for predicting successful osseointegration, clarifying the effects of the insertion load may contribute to improving the safety and success of implant treatment.
methodsStraight single-thread implants with pitches of 0.6 mm (S06) and 1.2 mm (S12) and double-thread implants with a 0.6 mm pitch (D06) were used (10 each). Insertion loads of the minimum required load, 5 N, 10 N, and 15 N were applied. Insertion torque values (ITVs), removal torque values (RTVs), and insertion times were measured (p = 0.05). The interface between the implants and the simulated bone was observed with a digital microscope under each load.
resultsThe minimum insertion load was greatest in the order of S12 < S06 < D06. Variation in the insertion load did not affect the ITV or RTV, but lower loads extended the insertion time. Increased insertion loads led to more voids caused by bone fragment loss, especially in the double-thread designs.
conclusionsWhile the insertion load did not directly influence the ITV or RTV, it varied by implant design. Higher loads potentially damage the surrounding bone, indicating the importance of careful load management.