Evidence map›Paper›PMID 40849465›Full record

ArticleBMC oral health2025

Comparative evaluation of the cyclic fatigue resistance of four Ni-Ti instruments in simulated root canal curvatures using CAD/CAM technology.

Tuğçenur Yıldız, Recai Zan

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tuğçenur YıldızDepartment of Endodontics, Faculty of Dentistry, Sakarya University, Sakarya, 54100, Turkey. dttugceyildiz@gmail.com.
Recai ZanDepartment of Endodontics, Faculty of Dentistry, Sivas Cumhuriyet University, Sivas, 58140, Turkey.

Funding

Scientific Research Project Fund of Sivas Cumhuriyet University DIS-262
6 · The paper itself

Abstract

backgroundThis study aimed to evaluate and compare the cyclic fatigue resistance of new generation nickel-titanium file systems in simulated single and double curvature ceramic root canals.

methodsA total of 80 Nickel-Titanium (Ni-Ti) instruments-TruNatomy (TN) (26/0.04), WaveOne Gold (WOG) (25/0.07), Reciproc Blue (RecB) (25/0.08), and One Curve (OC) (25/0.04)-were tested under simulated intracanal thermal conditions (35 ± 0.1 °C). The instruments were evaluated within custom-designed artificial canals fabricated from ceramic blocks, incorporating either a single curvature (SC; 60° angle, 5 mm radius) or a double curvature configuration (DC; coronal bend: 60°, 5 mm radius; apical bend: 60°, 2 mm radius). For each instrument, the time until fracture occurred was recorded, and the number of cycles to failure (NCF) was calculated accordingly. Fragment lengths (FLs) were measured using a digital microcaliper, and the topography of the fracture surfaces was analyzed through scanning electron microscopy (SEM). Data were statistically assessed using non-parametric Kruskal-Wallis and Mann-Whitney U tests, with significance defined at the p-value threshold of < 0.05.

resultsRecB files demonstrated the highest NCF in the SC group (p < 0.05). TN and OC had significantly lower NCF than RecB (p < 0.05) but were statistically similar (p > 0.05). WOG recorded the lowest NCF in SC (p < 0.05). In the DC group, WOG also showed the lowest NCF (p < 0.05), with no significant differences among the other three files (p > 0.05). SEM analysis revealed that nearly all fractured instruments exhibited a ductile fracture pattern, characterized by the presence of microcavities and pits, which are typically associated with cyclic fatigue failure.

conclusionsSelecting Ni-Ti file systems based on canal anatomy is essential for minimizing fatigue-related failures. RecB exhibited superior resistance in SC canals, while WOG showed consistently lower performance in both configurations, warranting cautious use in curved canals. These findings underscore the importance of matching instrument selection to canal morphology and mechanical demands to ensure safe and predictable clinical outcomes.

Indexed as

Computer-Aided DesignDental InstrumentsDental Pulp CavityNickelRoot Canal PreparationTitaniumDental Stress AnalysisEquipment DesignEquipment FailureHumansMaterials TestingMicroscopy, Electron, ScanningNickelTitaniumtitanium nickelideCAD/CAMCeramic blockCyclic fatigueEndodontic kinematicsSEM

Identifiers

PMID40849465
PMCPMC12374312

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.