ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2026
The atlantoaxial distance ratio (AADR): proposal and validation of a novel radiographic parameter for the evaluation vertical atlantoaxial dislocation in a preliminary descriptive study.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesVertical atlantoaxial dislocation (VAAD) is a clinically significant but often overlooked component of atlantoaxial instability, yet a reliable, universally applicable radiographic parameter for its quantification is lacking. This preliminary study proposes and validates a novel metric, the atlantoaxial distance ratio (AADR), for the radiographic assessment of VAAD. MATERIALS AND
methodsThe AADR is calculated on lateral cervical radiographs as the ratio of the mean vertical distance from the C1 superior tubercles to the C2 inferior endplate, divided by the anteroposterior diameter of the C2 inferior endplate. A preliminary reference range for AADR was determined in 46 asymptomatic volunteers. Subsequently, a retrospective analysis was conducted on 13 patients with VAAD who underwent single-stage posterior reduction and fusion using C2 lateral mass-isthmus screws between January 2022 and April 2023. Pre- and postoperative AADR, atlanto-dental interval (PADI), spinal canal diameter on MRI (d-MRI), visual analogue scale (VAS) for pain, and modified Japanese Orthopedic Association (JOA) scores were evaluated. A composite reference standard (CRS) was established based on a blinded review by an expert panel. The diagnostic accuracy of AADR was evaluated using receiver operating characteristic (ROC) curve analysis.
resultsThe mean AADR in the normal cohort was 1.87 ± 0.08 (range: 1.80-2.06). In patients with VAAD, the mean preoperative AADR was significantly lower at 1.78 ± 0.10 (p = 0.0015 vs. normal), and it significantly increased to 2.07 ± 0.12 postoperatively (p < 0.0001), a value not significantly different from the normal range (p > 0.05). Surgical reduction also resulted in significant improvements in PADI (from 7.31 ± 1.32 mm to 15.77 ± 1.24 mm, p < 0.0001), d-MRI (from 6.62 ± 1.26 mm to 15.00 ± 1.22 mm, p < 0.0001), VAS scores (from 4.77 ± 1.01 to 0.77 ± 0.60, p < 0.0001), and JOA scores (from 9.08 ± 3.14 to 12.46 ± 2.47, p < 0.0001). The area under the ROC curve (AUC) for AADR was 0.901, indicating high diagnostic accuracy. The Youden's J index identified an optimal diagnostic threshold at an AADR value of 1.83 with a sensitivity of 88.9% and a specificity of 73.2%.
conclusionThis preliminary study suggests that the AADR is a promising and reproducible radiographic parameter for quantifying VAAD. An AADR value below 1.83 may suggest the presence of VAAD; however, this proposed threshold requires validation in larger, multicenter studies. Restoring it to the normal range signifies successful reduction. Correcting VAAD is crucial for achieving effective neural decompression and creating optimal conditions for fusion.
Indexed as
Identifiers
40848154What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.