Evidence map›Paper›PMID 40848141›Full record

ArticleEuropean radiology2026

Pushing the limits of cardiac MRI: deep-learning based real-time cine imaging in free breathing vs breath hold.

Ann-Christin Klemenz, Lena-Maria Watzke, Karolin K Deyerberg, Benjamin Böttcher, Margarita Gorodezky, Mathias Manzke, Antonia Dalmer, Roberto Lorbeer, Marc-André Weber, Felix G Meinel

Abstract read
In one paragraph

Article in European radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ann-Christin KlemenzInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Lena-Maria WatzkeInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Karolin K DeyerbergInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Benjamin BöttcherInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Margarita GorodezkyGE HealthCare, Munich, Germany.
Mathias ManzkeInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Antonia DalmerInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Roberto LorbeerDepartment of Radiology, Ludwig-Maximilians University, Munich, Germany.
Marc-André WeberInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Felix G MeinelInstitute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, Rostock University Medical Center, Rostock, Germany. felix.meinel@med.uni-rostock.de.ORCID http://orcid.org/0000-0002-3201-1033

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate deep-learning (DL) based real-time cardiac cine sequences acquired in free breathing (FB) vs breath hold (BH). MATERIALS AND

methodsIn this prospective single-centre cohort study, 56 healthy adult volunteers were investigated on a 1.5-T MRI scanner. A set of real-time cine sequences, including a short-axis stack, 2-, 3-, and 4-chamber views, was acquired in FB and with BH. A validated DL-based cine sequence acquired over three cardiac cycles served as the reference standard for volumetric results. Subjective image quality (sIQ) was rated by two blinded readers. Volumetric analysis of both ventricles was performed.

resultssIQ was rated as good to excellent for FB real-time cine images, slightly inferior to BH real-time cine images (p < 0.0001). Overall acquisition time for one set of cine sequences was 50% shorter with FB (median 90 vs 180 s, p < 0.0001). There were significant differences between the real-time sequences and the reference in left ventricular (LV) end-diastolic volume, LV end-systolic volume, LV stroke volume and LV mass. Nevertheless, BH cine imaging showed excellent correlation with the reference standard, with an intra-class correlation coefficient (ICC) > 0.90 for all parameters except right ventricular ejection fraction (RV EF, ICC = 0.887). With FB cine imaging, correlation with the reference standard was good for LV ejection fraction (LV EF, ICC = 0.825) and RV EF (ICC = 0.824) and excellent (ICC > 0.90) for all other parameters.

conclusionDL-based real-time cine imaging is feasible even in FB with good to excellent image quality and acceptable volumetric results in healthy volunteers. KEY POINTS: Question Conventional cardiac MR (CMR) cine imaging is challenged by arrhythmias and patients unable to hold their breath, since data is acquired over several heartbeats. Findings DL-based real-time cine imaging is feasible in FB with acceptable volumetric results and reduced acquisition time by 50% compared to real-time breath-hold sequences. Clinical relevance This study fits into the wider goal of increasing the availability of CMR by reducing the complexity, duration of the examination and improving patient comfort and making CMR available even for patients who are unable to hold their breath.

Indexed as

Breath HoldingDeep LearningHeartMagnetic Resonance Imaging, CineAdultFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedProspective StudiesRespirationAccelerated imagingCardiac MRClinical imagingDeep learningFree breathing

Identifiers

PMID40848141
PMCPMC12953295

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.