Evidence map›Paper›PMID 40845115›Full record

ArticleScience advances2025

Bayesian reconstruction of rapidly scanned mid-infrared optoacoustic signals enables fast, label-free chemical microscopy.

Constantin Berger, Myeongseop Kim, Lukas Scheel-Platz, Andreas Eigenberger, Lukas Prantl, Panhang Liu, Vipul Gujrati, Vasilis Ntziachristos, Dominik Jüstel, Miguel A Pleitez

Abstract read
In one paragraph

Article in Science advances, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Constantin BergerInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0001-5528-4870
Myeongseop KimInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0001-8100-5521
Lukas Scheel-PlatzInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0003-0809-9634
Andreas EigenbergerDepartment of Plastic, Hand, and Reconstructive Surgery, University Medical Center Regensburg, Regensburg, Germany.ORCID 0000-0002-2141-8786
Lukas PrantlDepartment of Plastic, Hand, and Reconstructive Surgery, University Medical Center Regensburg, Regensburg, Germany.ORCID 0000-0003-2454-2499
Panhang LiuInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0009-0008-5609-1251
Vipul GujratiInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0003-2586-0210
Vasilis NtziachristosInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0002-9988-0233
Dominik JüstelInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0002-5464-6291
Miguel A PleitezInstitute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany.ORCID 0000-0002-7379-4409

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hyperspectral optoacoustic microscopy (OAM) enables obtaining images with label-free biomolecular contrast, offering excellent perspectives as a diagnostic tool to assess freshly excised and unprocessed biological samples. However, time-consuming raster scanning image formation currently limits the translation potential of OAM into the clinical setting, for instance, in intraoperative histopathological assessments, where micrographs of excised tissue need to be taken within a few minutes for fast clinical decision-making. Here, we present a non-data-driven computational framework tailored to enable fast OAM by rapid data acquisition and model-based image reconstruction, termed Bayesian raster-computed optoacoustic microscopy (BayROM). Unlike data-driven approaches, BayROM does not require training datasets, but instead, it uses probabilistic model-based reconstruction to facilitate fast high-resolution imaging. We show that BayROM enables acquiring micrographs 10 times faster on average than conventional raster scanning microscopy and provides sufficient image quality to facilitate the intraoperative histological assessment of processed fat grafts for autologous fat transfer.

Indexed as

Image Processing, Computer-AssistedMicroscopyPhotoacoustic TechniquesAlgorithmsBayes TheoremHumansInfrared Rays

Identifiers

PMID40845115
PMCPMC12372899

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked