Evidence map›Paper›PMID 40844453›Full record

ArticleJACC. Asia2025

Characteristics of Effective Antitachycardia Pacing for Ventricular Tachycardia: The Importance of True Septal Lead Position.

Satoshi Yanagisawa, Yasuya Inden, Yuki Sato, Ryo Watanabe, Hiroyuki Miyazawa, Kiichi Miyamae, Tomoya Iwawaki, Takayuki Goto, Shun Kondo, Masaya Tachi and 4 more

Abstract read
In one paragraph

Article in JACC. Asia, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Satoshi YanagisawaDepartment of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, Nagoya, Japan; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan. Electronic address: yanagisawa-sato@med.nagoya-u.ac.jp.
Yasuya IndenDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Yuki SatoDepartment of Clinical Engineering, Nagoya University Hospital, Nagoya, Japan.
Ryo WatanabeDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Hiroyuki MiyazawaDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Kiichi MiyamaeDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Tomoya IwawakiDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Takayuki GotoDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Shun KondoDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Masaya TachiDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Masafumi ShimojoDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Yukiomi TsujiDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Takahiro OkumuraDepartment of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, Nagoya, Japan; Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Toyoaki MuroharaDepartment of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAntitachycardia pacing (ATP) has a potential benefit for shock reduction of implantable cardioverter-defibrillator (ICD) recipients; however, its clinical utility and characteristics are unknown.

objectivesThis study aims to extract characteristics leading to a high ventricular tachycardia (VT) termination rate of ATP.

methodsPatients who had a history of ≥1 ATP treatment episode from ICD or cardiac resynchronization therapy-defibrillator (CRTD) devices were included. All ATP treatments wherein intracardiac electrograms could be traced were reviewed. Two endpoints of VT termination were defined: type-I break (termination with 0-1 beat) and clinical endpoint of termination (≤5 beats). We assessed the characteristics associated with a high success rate of ATP using the logistic regression generalized estimating equation method.

resultsOf 756 recipients using high-power devices, 1,468 treatment episodes in 119 patients were analyzed. The VT rate of <188 beats/min (vs ≥188 beats/min), CRTD (vs ICD), and true septum right ventricular lead position were significantly associated with high success rate of type-I break termination (generalized estimating equation success rate: 78.7% vs 64.7%, P = 0.011; 80.1% vs 66.5%, P = 0.021; and 79.8% vs 60.5%, P = 0.023, respectively). True septum lead position and slow VT were also independently associated with successful termination with clinical endpoint. The termination rate was highest in the right ventricular true septum position across all positions at both endpoints. The pacing QRS interval was significantly shorter in the septum group than in the nonseptum group (166.2 ± 21.9 ms vs 198.7 ± 26.5 ms; P < 0.001).

conclusionsTrue septum lead position, in addition to slow VT and CRTD, may be key to high ATP termination success.

Indexed as

antitachycardia pacingcardiac resynchronization therapy defibrillatorimplantable cardioverter-defibrillatortrue septum pacingventricular tachycardia

Identifiers

PMID40844453
PMCPMC12790063

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.