Evidence map›Paper›PMID 40842881›Full record

ArticleJournal of the Optical Society of America. A, Optics, image science, and vision2021

High-speed multiview imaging approaching 4pi steradians using conic section mirrors: theoretical and practical considerations.

Kevin C Zhou, Al-Hafeez Dhalla, Ryan P McNabb, Ruobing Qian, Sina Farsiu, Joseph A Izatt

Abstract read
In one paragraph

Article in Journal of the Optical Society of America. A, Optics, image science, and vision, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. High-speed multiview imaging approaching 4pi steradians using conic section mirrors: theoretical and practical considerations.Journal of the Optical Society of America. A, Optics, image science, and vision · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kevin C ZhouDepartment of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.ORCID 0000-0002-0351-8812
Al-Hafeez DhallaDepartment of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.
Ryan P McNabbDepartment of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27708, USA.ORCID 0000-0002-1686-4191
Ruobing QianDepartment of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.
Sina FarsiuDepartment of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.ORCID 0000-0003-4872-2902
Joseph A IzattDepartment of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA.

Funding

VISION RESEARCHP30EY005722 · NEI · DUKE UNIVERSITY · PI Vadim Y Arshavsky · 1985 to 2026
$19.3M
Intraoperative OCT Guidance of Intraocular SurgeryU01EY028079 · NEI · DUKE UNIVERSITY · PI KUO, ANTHONY NANLIN, TOTH, CYNTHIA ANN · 2018 to 2022
$3.8M
NEI NIH HHS P30 EY005722NEI NIH HHS U01 EY028079
6 · The paper itself

Abstract

Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography, optical diffraction tomography, synthetic aperture microscopy, Fourier ptychographic microscopy, structured illumination microscopy, photogrammetry, and optical coherence refraction tomography. The wider the angular coverage, the better the resolution enhancement or 3D-resolving capabilities. However, achieving such angular ranges is a practical challenge, especially when approaching ±90° or beyond. Often, researchers resort to expensive, proprietary high numerical aperture (NA) objectives or to rotating the sample or source-detector pair, which sacrifices temporal resolution or perturbs the sample. Here, we propose several new strategies for multiangle imaging approaching 4pi steradians using concave parabolic or ellipsoidal mirrors and fast, low rotational inertia scanners, such as galvanometers. We derive theoretically and empirically relations between a variety of system parameters (e.g., NA, wavelength, focal length, telecentricity) and achievable fields of view (FOVs) and importantly show that intrinsic tilt aberrations do

Identifiers

PMID40842881
PMCPMC12366490

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.