Evidence map›Paper›PMID 40841600›Full record

Observational studyBMC cardiovascular disorders2025

Hemodynamics assessment using 4D flow CMR before and after balloon pulmonary angioplasty in chronic thromboembolic pulmonary hypertension: a retrospective observational study.

Kazuto Ohno, Kenichiro Suwa, Keitaro Akita, Ryota Sato, Terumori Satoh, Yuichiro Maekawa

Abstract readObservational Study
In one paragraph

Observational study in BMC cardiovascular disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kazuto OhnoDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan.
Kenichiro SuwaDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan. k-suwa@hama-med.ac.jp.
Keitaro AkitaDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan.
Ryota SatoDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan.
Terumori SatohDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan.
Yuichiro MaekawaDivision of Cardiology, Internal Medicine III, Hamamatsu University School of Medicine, 1-20-1 Handayama, Chuo-ku, Hamamatsu, 431-3192, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe effect of balloon pulmonary angioplasty (BPA) on hemodynamics in chronic thromboembolic pulmonary hypertension (CTEPH), assessed using time-resolved three-dimensional cine phase-contrast cardiac magnetic resonance (4D flow CMR), remains unclear. Therefore, the present study aimed to investigate the hemodynamic features of the pulmonary artery (PA) before and after BPA and the diagnostic performance of 4D flow CMR-derived hemodynamics before BPA to predict the achievement of mean pulmonary artery pressure (mPAP) < 30 mmHg after BPA.

methodsTwenty-one patients with CTEPH who underwent 4D flow CMR before and after BPA were retrospectively enrolled. Regarding 4D flow CMR, the analysis included peak flow volume and velocity at the main PA and peak systolic wall shear stress (WSS).

resultsSeventeen patients achieved a mPAP < 30 mmHg after BPA. Peak flow velocity at the main PA (262.8 ± 52.3 mm/s vs. 298.5 ± 68.3 mm/s, p = 0.015) and peak WSS (0.97 ± 0.26 Pa vs. 1.13 ± 0.37 Pa, p = 0.044) both increased after BPA compared to their values before BPA. Receiver operating characteristic analysis was performed to predict mPAP ≥ 30 mmHg after BPA based on peak flow velocity and peak WSS before BPA. The analysis revealed an area under the curve of 0.926 (p < 0.001) for peak flow velocity before BPA (sensitivity, 0.765; specificity, 0.750; cut-off, < 251 mm/s) and 0.971 (p < 0.001) for peak WSS before BPA (sensitivity, 0.882; specificity, 1.00; cut-off, < 0.89 Pa).

conclusionsBased on the study results, 4D flow CMR imaging showed improvement in hemodynamics after BPA. Furthermore, peak flow velocity and peak WSS were useful metrics for predicting the achievement of catheter-based BPA goal of mPAP < 30 mmHg with a better prognosis.

Indexed as

Angioplasty, BalloonArterial PressureHemodynamicsHypertension, PulmonaryMagnetic Resonance Imaging, CinePerfusion ImagingPulmonary ArteryPulmonary CirculationPulmonary EmbolismAdultAgedBlood Flow VelocityChronic DiseaseFemaleHumansMale4D flow CMRChronic thromboembolic pulmonary hypertensionWall shear stress

Identifiers

PMID40841600
PMCPMC12369117

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.