ArticleClinical neuroradiology2026
Development and Validation of a Novel Stenosis Model for Percutaneous Transluminal Angioplasty Training of the Internal Carotid Artery.
Article in Clinical neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
INTRODUCTION/
backgroundThe rising demand for endovascular stroke therapy highlights the need for standardized training environments. Studies have shown the positive impact of simulator-based training for neurointerventional procedures. Given the frequent use of percutaneous transluminal angioplasty (PTA) of the internal carotid artery (ICA) in acute settings, specialized simulation training is crucial. This study evaluates the feasibility of a custom-made ICA stenosis model for PTA simulation.
methodsInternally developed 3D-printed circular clamps were attached to patient-based 3D printed ICA models and integrated into a previously described realistic whole-body neurovascular simulation model HANNES (Hamburg Anatomic Neurointerventional Endovascular Simulator) to simulate a proximal ICA stenosis. Participants (N = 5) of varying experience levels each performed three PTA procedures. Fluoroscopy time, radiation doses, and the extent of stenosis and balloon inflation pressure were assessed. After simulation, participants rated the model in terms of haptic, feasibility and applicability.
resultsFor statistical analysis, the participants were divided into two groups according to their experience level. There was a statistically significant difference in the procedure duration between both groups, U = 10.500, Z = -1.968, p < 0.05. Significant test results could also be demonstrated for radiation doses (DAP) among groups, Kolmogorov-Smirnov p < 0.05, U = 7.000, Z = -2.357, p < 0.05. No difference was shown between the total contrast volume (ml) among groups that was used during procedures (m = 11.67, SD 2.09).
conclusionThe authors propose a novel ICA stenosis simulation model for training of the cervical PTA. The model provides a realistic and replicable method for standardized procedural training.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.