Evidence map›Paper›PMID 40837448›Full record

ArticleJournal of biomedical optics2025

Deep-learning-based endoscopic single-shot fringe projection profilometry.

Ruizhi Zuo, Shuwen Wei, Yaning Wang, Ruichen Huang, Wayne Wonseok Rodgers, Jinglun Yu, Michael H Hsieh, Axel Krieger, Jin U Kang

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ruizhi ZuoJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-0464-6234
Shuwen WeiJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0001-8679-9615
Yaning WangJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0009-0000-9085-8278
Ruichen HuangJohns Hopkins University, Department of Mechanical Engineering, Baltimore, Maryland, United States.
Wayne Wonseok RodgersJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0009-0004-6897-3279
Jinglun YuJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.
Michael H HsiehChildren's National Hospital, Division of Urology, Washington, DC, United States.
Axel KriegerJohns Hopkins University, Department of Mechanical Engineering, Baltimore, Maryland, United States.
Jin U KangJohns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.

Funding

Next Generation Robotic System for Supervised-Autonomous Bowel AnastomosisR56EB033807 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI HSIEH, MICHAEL HARRISON, KANG, JIN U · 2023 to 2023
$748k
NIBIB NIH HHS R56 EB033807
6 · The paper itself

Abstract

Significance: Conventional fringe projection profilometry (FPP) requires multiple image acquisitions and therefore long acquisition times that make it slow for high-speed dynamic measurements. We propose and demonstrate a deep-learning-based single-shot FPP system utilizing a single endoscope for surgical guidance. Aim: We aim to achieve real-time depth map generation of target tissues with high accuracy for robotic surgical guidance. Approach: We proposed an endoscopic single-shot FPP system based on a deep learning network to generate real-time accurate tissue depth maps for surgical guidance. The system utilizes a dual-channel endoscope, where one channel projects fringe patterns from a projector and the other channel collects images using a camera. In addition, we developed a data synthesis method to generate a large number of diverse training datasets. The network consists of MaskNet, which segments the tissue from the background, and DepthNet, which predicts the depth map of the image. The results from both networks are combined to generate the final depth map. Results: We tested our algorithm using fringe patterns with different frequencies and found that the optimal frequency for single-shot FPP in our setup is 20 Hz. The algorithm has been tested on both synthetic and experimental data, achieving a maximum depth prediction error of Conclusion: A deep-learning-based single-shot FPP endoscopic system was shown to be highly effective in real-time depth map generation with millimeter-scale error. Implementing such a system has the potential to improve the reliability of image-guided robotic surgery.

Indexed as

Deep LearningEndoscopyImage Processing, Computer-AssistedSurgery, Computer-AssistedAlgorithmsHumansRobotic Surgical Procedures3D optical imagingdeep learningendoscopefringe projection profilometrysurgery guidance

Identifiers

PMID40837448
PMCPMC12364446

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.