ArticleJournal of medical biochemistry2025
Improved potassium reliability in whole blood through hemolysis detection on the novel GEM Premier 7000 blood gas analyzer.
Article in Journal of medical biochemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Hemolysis is the most frequent preanalytical error in clinical laboratories, but its detection in point-of-care (POC) settings remains challenging due to the lack of sample separation. This study was planned to validate the hemolysis index (HI) threshold of GEM Premier 7000 blood gas analyzer for detecting hemolysis levels that may generate clinically significant interference in potassium measurement. Methods: Heparinized whole blood samples were collected from healthy volunteers and divided into six aliquots; one was used as non-hemolyzed control, while hemolysis was mechanically induced in the remaining five aliquots by repeated aspirations through a fine-gauge needle. HI and potassium were measured on GEM Premier 7000. Results: The final study population consisted of 18 volunteers. Both HI and potassium levels increased progressively and significantly with the number of fine-needle aspirations (p<0.001 for both). A strong positive correlation was observed between HI values and percentage increases in potassium concentration in hemolyzed aliquots (r=0.985, p<0.001). Receiver operating characteristic (ROC) curve analysis confirmed excellent diagnostic accuracy of HI in detecting potassium increases above the minimum total 7.4% allowable error threshold, with an area under the curve (AUC) of 1.00 and optimal cutoff of 102 mg/dL (0.94 sensitivity and 1.00 specificity). At the manufacturer-recommended 116 mg/dL threshold, the AUC was 0.95, with 0.89 sensitivity and 1.00 specificity. Conclusions: These results confirm that the novel GEM Premier 7000 blood gas analyzer provides accurate detection of hemolysis thresholds in whole blood that may impair potassium test reliability.