ArticleBMC medical imaging2025

A novel methodology for measuring global diaphragm thickness by ultrasonography in patients with critical illness: an exploratory pilot study.

Chen-Liang Sun, Si-Ping Zhou, Li-Sha Hou, Meng-Jie Zhan, Yi-Ping Wang, Hong-Sheng Zhao, Feng-Mei Guo, Guang-Quan Zhou

Abstract read
In one paragraph

Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chen-Liang Sun *Department of Critical Care Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China.
Si-Ping Zhou *State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, No. 2 of Sipailou, Xuanwu District, Nanjing, 210096, China.
Li-Sha HouDepartment of Critical Care Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China.
Meng-Jie ZhanDepartment of Critical Care Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China.
Yi-Ping WangDepartment of Critical Care Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China.
Hong-Sheng ZhaoDepartment of Critical Care Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China.
Feng-Mei GuoJiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, No. 87 of Dingjiaqiao, Hunan Road, Nanjing, 210009, China. fengmeiguogfm03@126.com.
Guang-Quan ZhouState Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, No. 2 of Sipailou, Xuanwu District, Nanjing, 210096, China. gqzzhouguangquan@163.com.

Funding

National Science and Technology Major Project of China 2022YFC2504505Scientific Research Project Foundation of Nantong Municipal Health Commission MS2024015
6 · The paper itself

Abstract

backgroundA global diaphragm thickness measurement technique was developed for the zone of apposition (ZOA) using an image edge identification approach. The method was assessed in terms of its repeatability and reliability when applied in patients with critical illness.

methodsDiaphragm thickness measurements were conducted by experienced ultrasound examiners in 60 critically ill adult patients. The performance of continuous global diaphragm thickness measurements was compared to traditional localized diaphragm thickness measurements with regard to intra-observer and inter-observer consistency.

resultsEnd-expiratory diaphragm thickness was measured to assess consistency. For the traditional local diaphragm thickness measurements, the intraclass correlation coefficients (ICC) were 0.882 for intra-observer and 0.848 for inter-observer assessments (p < 0.001). The global diaphragm thickness measurements yielded ICC values of 0.968 and 0.955 for intra-observer and inter-observer assessments, respectively (p < 0.001). These findings indicated good reliability for the conventional method and excellent reliability for the global measurement method. The maximum observed variability was 16.5% with the traditional method and 3.9% with the continuous measurement approach. When using a 10% decrease in diaphragm thickness as the threshold for clinically relevant diaphragmatic atrophy, 16.7% of measurements obtained through the traditional method exceeded this error margin, whereas all measurements acquired through the continuous method remained within the acceptable range.

conclusionsCompared to traditional localized diaphragm thickness ultrasonography, the continuous approach demonstrated superior repeatability and reliability. This newly developed methodology may enhance the precision of diaphragm thickness evaluations within the ZOA in patients with critical illness.

Indexed as

Critical IllnessDiaphragmAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedObserver VariationPilot ProjectsReproducibility of ResultsUltrasonographyDiaphragm thicknessIntensive care unitReliabilityTest reproducibilityUltrasonography

Identifiers

PMID40836287
PMCPMC12366372

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.