ArticleScientific reports2025

Micron scale binary periodic phase plate for increased depth of focusing based on a non local analysis and design.

Morteza Khoshhal, Mahmoud Shahabadi

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Morteza KhoshhalPhotonics Research Laboratory, Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran.
Mahmoud ShahabadiPhotonics Research Laboratory, Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran. shahabad@ut.ac.ir.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to focus light at a desired depth, wavefront shaping of the incident light is required. Light focusing is used in applications such as medical imaging, sensing, power dividers, etc. For this purpose, various phase plates can be exploited, but we propose a periodic phase plate. The reason for considering periodic structures is to profit from wavefront shaping of several periods to focus light at larger depths, which can be a challenging task without a periodic phase plate. Using this method, the focus quality is such that its Full Width at Half Maximum (FWHM) reaches in the order of the diffraction limit, while maximizing power concentration. We also assume that the phase plate elements are of micron-scale, so that it does not require nanofabrication. The modelling and analysis method used in this paper accurately takes the coupling among adjacent phase plate elements into account, i.e., it does not rely on local phase approximation. Since the introduced phase plate has a periodic structure, the focusing is repeated periodically, which finds several applications. Using our computational technique, one is able to rigorously analyze and design phase plates as wide as [Formula: see text]. In a sample design, we show that [Formula: see text] of the illuminated power reaches a depth of [Formula: see text] or 1m at a wavelength of [Formula: see text]. Approximately [Formula: see text] of the incident power is focused within only [Formula: see text] of the unit cell width. Moreover, despite large depth of focusing, its FWHM is in the order of the diffraction limit. In this paper, in addition to achieving light focusing at larger depths, we also demonstrate that the proposed methodology can be utilized for focusing with a FWHM close to the diffraction limit down to [Formula: see text], double focusing, and focusing with a high Numerical Aperture (NA) of 0.97.

Identifiers

PMID40830564
PMCPMC12365050

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.