Evidence map›Paper›PMID 40828853›Full record

ArticlePloS one2025

Triple-band highly sensitive terahertz metamaterial absorber for biomedical sensing applications.

Asad Miah, Sams Al Zafir, Md Hasnain, Joyonta Das, Sayed Muhammad Anowarul Haque, Abdul Wahed

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Asad MiahDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.ORCID https://orcid.org/0009-0006-9369-3273
Sams Al ZafirDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.
Md HasnainDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.
Joyonta DasDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.
Sayed Muhammad Anowarul HaqueDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.
Abdul WahedDepartment of Electrical and Electronic Engineering, Mymensingh Engineering College, Mymensingh, Bangladesh.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Due to the growing interest in metamaterials for biomedical applications, this study presents the design and analysis of a novel, compact, triple-band metamaterial absorber for biological sensing in the terahertz range. The structure, with dimensions of 41 × 41 μm2, exhibits exceptionally high absorption rates above 99% at three distinct resonance frequencies of 1.85, 3.62, and 5.63 THz. To validate the design, an equivalent circuit model was created and evaluated alongside electric field, magnetic field, and surface current distributions. A key focus of this work is the sensor's performance, evaluated by introducing a sensing layer with varying refractive indices. The absorber demonstrates outstanding sensitivity values of 1.5 THz/RIU, 1 THz/RIU, and 0.66 THz/RIU at the third, second, and first resonances, respectively, indicating highly reliable sensing performance across multiple frequency bands. Furthermore, its suitability for biochemical applications was evaluated by testing its ability to detect different samples, such as glucose, malaria, and cervical cancer cells. The absorber also demonstrates strong performance metrics, with a maximum quality factor of 39.13 and a figure of merit (FoM) of 6.95, supporting its reliability. Additionally, its suitability for microwave imaging (MWI) technology is also examined. The combination of near-perfect absorption and high sensitivity makes this compact metamaterial absorber a promising candidate for advanced biomedical sensing and diagnostic technologies.

Indexed as

Biosensing TechniquesTerahertz RadiationGlucoseHumansGlucose

Identifiers

PMID40828853
PMCPMC12364324

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked