Comparability of Daily-Life Walking Speed Measured by Smartphone GPS and Ankle-Band Accelerometer: Cross-Sectional Study.

Hisashi Kawai, Keigo Imamura, Rui Gong, Manami Ejiri, Shuichi Obuchi

Abstract readComparative Study
In one paragraph

Article in JMIR formative research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hisashi KawaiResearch Team for Human Care, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2 , Sakae-cho, Itabashi-ku, Tokyo, 1730015, Japan, 81 339643241 ext 4243, 81 339641844.ORCID 0000-0003-3015-6041
Keigo ImamuraResearch Team for Human Care, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2 , Sakae-cho, Itabashi-ku, Tokyo, 1730015, Japan, 81 339643241 ext 4243, 81 339641844.ORCID 0000-0002-6440-670X
Rui GongResearch Team for Human Care, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2 , Sakae-cho, Itabashi-ku, Tokyo, 1730015, Japan, 81 339643241 ext 4243, 81 339641844.ORCID 0000-0001-5112-5696
Manami EjiriResearch Team for Human Care, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2 , Sakae-cho, Itabashi-ku, Tokyo, 1730015, Japan, 81 339643241 ext 4243, 81 339641844.ORCID 0000-0003-3544-4587
Shuichi ObuchiResearch Team for Human Care, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2 , Sakae-cho, Itabashi-ku, Tokyo, 1730015, Japan, 81 339643241 ext 4243, 81 339641844.ORCID 0000-0003-0187-9275

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Daily-life walking speed (DWS), which is a critical health indicator in older adults, can be measured using smartphone GPS technology. Although this method is becoming more widely accessible, it is restricted to outdoor walking. In contrast, accelerometers can capture walking speed indoors; however, there is limited information on the comparability of DWS data between these two techniques. Objective: In this study, we aimed to investigate the agreement and systematic error between DWS measured using the built-in GPS of a smartphone and an ankle-band accelerometer. Methods: Participants were recruited from a previously selected cohort of community-dwelling older adults. Their DWS was assessed using both a smartphone app and ankle band accelerometer. Data from the two devices were matched based on simultaneous recordings, and agreement between the walking speeds was evaluated using the intraclass correlation coefficient (ICC) and a Bland-Altman plot. Results: A total of 99 participants (38 men, 61 women; mean [SD] age 71.5 [4.9] y) were included, yielding 3652 paired data points. The mean (SD) DWS as measured by GPS was 1.30 (0.19) m/s, and this was significantly higher than the value of 1.12 (0.23) m/s measured by the accelerometer (P<.001). The ICC(2, 1) (95% CI) value was 0.523 (-0.022 to 0.765), and the ICC(2, k) value was 0.687 (-0.045 to 0.867). The Bland-Altman plot revealed a fixed error of 0.18 m/s with 95% limits of agreement ranging from -0.49 m/s to 0.13 m/s in the GPS-measured walking speed compared to that measured by the ankle-band accelerometer. Conclusions: The GPS app consistently recorded a faster walking speed than the ankle-band accelerometer. The agreement between the measurements of the two devices was poor. The data suggest that a correction is necessary when comparing the DWS between these two devices.

Indexed as

AccelerometryGeographic Information SystemsSmartphoneWalkingWalking SpeedAgedAged, 80 and overCross-Sectional StudiesFemaleHumansIndependent LivingMaleMiddle AgedMobile Applicationsaccelerometerankle-band accelerometerdaily-life walking speedGPSsmartphonewalking speed assessmentwearable health technology

Identifiers

PMID40825225
PMCPMC12361537

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.