Evidence map›Paper›PMID 40824174›Full record

ArticleVeterinary medicine and science2025

The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas.

Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend

Abstract read
In one paragraph

Article in Veterinary medicine and science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sait SendagDeparment of Obstetrics and Gynecology, Van Yuzuncu Yil University, Van, Türkiye.ORCID https://orcid.org/0000-0002-0491-1800
Henrik WagnerVeterinary Clinic for Reproductive Medicine and Neonatology, Justus-Liebig-University, Giessen, Germany.ORCID https://orcid.org/0000-0001-8262-3751
Ali Osman TurgutDepartment of Animal Science, Faculty of Veterinary Medicine, Siirt University, Siirt, Türkiye.ORCID https://orcid.org/0000-0001-6863-0939
Davut KocaDeparment of Obstetrics and Gynecology, Van Yuzuncu Yil University, Van, Türkiye.ORCID https://orcid.org/0000-0002-7962-6959
Gerhard SchulerVeterinary Clinic for Reproductive Medicine and Neonatology, Justus-Liebig-University, Giessen, Germany.ORCID https://orcid.org/0000-0002-9412-3743
Axel WehrendVeterinary Clinic for Reproductive Medicine and Neonatology, Justus-Liebig-University, Giessen, Germany.ORCID https://orcid.org/0000-0002-3313-4852

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAnti-Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.

methodsIn this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at -20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra-assay coefficient of variation is between 2.7% and 3.3%.

resultsBlood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species (p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non-significant p values (alpaca: r = -0.165, p = 0.649; llama: r = -0.547, p = 0.160). In alpaca (n = 11) and llama geldings (n = 8), blood serum AMH levels were below 0.01 ng/mL (p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross-react with SAC AMH.

conclusionsIn gelding llamas and alpacas, AMH concentrations were below the limit of detection (<0.01 ng/mL), which was significantly lower compared to intact animals (p < 0.001). The Elecsys AMH assay is therefore considered a suitable method for detecting gonadal tissue in SAC.

Indexed as

Anti-Mullerian HormoneCamelids, New WorldAnimalsImmunoassayMaleSensitivity and SpecificityAnti-Mullerian HormoneAMH assayanti‐Müllerian hormoneSouth American camelids

Identifiers

PMID40824174
PMCPMC12359723

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.