Article in Orthopaedic journal of sports medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jocelyn R WittsteinDepartment of Orthopaedic Surgery, Duke University School of Medicine, Durham, North Carolina, USA.
Marcos D TejadaDepartment of Research, Arthrex, Inc, Naples, Florida, USA.
Benjamin L SmithDepartment of Research, Arthrex, Inc, Naples, Florida, USA.
Brian C WernerDepartment of Orthopaedic Surgery, University of Virginia, Charlottesville, Virginia, USA.
Rachel M FrankDepartment of Orthopedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, USA.
Oliver L HauckDepartment of Research, Arthrex, Inc, Naples, Florida, USA.
Coen A WijdicksDepartment of Research, Arthrex, Inc, Naples, Florida, USA.ORCID https://orcid.org/0000-0003-1831-6161

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Reruptures and functional deficits can occur with conventional transosseous quadriceps tendon repair. Previous work has demonstrated the biomechanical superiority of adjustable transosseous metal cortical button fixation over conventional repair. Knotless all-suture anchor (ASA) buttons may provide a similar improvement but have not yet been investigated. Purpose: To biomechanically compare adjustable transosseous cortical fixation with knotless ASAs to traditional transosseous repair. Study Design: Controlled laboratory study. Methods: Eight matched pairs of male cadaveric knees were dissected to isolate and release the quadriceps tendon insertion. Paired knees were randomized to 2.6-mm knotless ASA or control repair, both with Krackow suturing using 1.7-mm suture tape. The ASA technique had two 1.6-mm tunnels through which the knotless ASA loops interlocked with the Krackow sutures. The control technique had three 2.4-mm tunnels through which suture tape tails were passed and tied over bone bridges. Knees were mounted onto a materials testing system and actuated from 5° to 90° of flexion via the quadriceps tendon for 10 native preconditioning cycles and 250 cycles after repair 0.1 Hz, with a peak force of 150 N per cycle. Repairs were loaded to failure at a rate of 50 mm/min. Outcomes included plastic gap formation (mm) during cyclic loading and stiffness (N/mm), yield load (N), and ultimate load (N) during load to failure. Paired Results: The ASA had significantly less gap formation at cycle 250 (mean Δ = 6.3 mm; Conclusion: Compared with conventional transosseous quadriceps tendon repair, adjustable ASA transosseous repair had 64% less tendon-bone gap formation, 35% greater stiffness, 21% greater yield load, and 27% greater ultimate load. Clinical Relevance: Adjustable knotless ASA cortical fixation is a viable alternative for transosseous quadriceps tendon repair that increases repair strength and reduces patellar tunnel drilling.

Indexed as

all-suture anchorkneepatellaquadriceps tendon repairtransosseous

Identifiers

PMID40823641
PMCPMC12357032

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.