Evaluation of the analytical and clinical characteristics of the siemens immulite®2000 tsi method for determining thyrotropin receptor antibodies.

Neda Milinković, Marija Sarić, Ana Ružanović, Miloš Žarković, Jasmina Ćirić, Iva Perović Blagojević, Ana-Marija Mastilović, Svetlana Ignjatović, Biljana Nedeljković Beleslin

Abstract read
In one paragraph

Article in Journal of medical biochemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Neda MilinkovićUniversity of Belgrade, Faculty of Pharmacy, Department of Medical Biochemistry, Belgrade.
Marija SarićUniversity of Belgrade, Faculty of Pharmacy, Department of Medical Biochemistry, Belgrade.
Ana RužanovićUniversity of Belgrade, Faculty of Pharmacy, Department of Medical Biochemistry, Belgrade.
Miloš ŽarkovićUniversity Clinical Center of Serbia, Clinic of Endocrinology, Belgrade, Serbia.
Jasmina ĆirićUniversity Clinical Center of Serbia, Clinic of Endocrinology, Belgrade, Serbia.
Iva Perović BlagojevićClinical Hospital Center "Dr Dragiša Mišović-Dedinje", Service for laboratory diagnostics, Belgrade.
Ana-Marija MastilovićClinical Hospital Center "Dr Dragiša Mišović-Dedinje", Service for laboratory diagnostics, Belgrade.
Svetlana IgnjatovićUniversity of Belgrade, Faculty of Pharmacy, Department of Medical Biochemistry, Belgrade.
Biljana Nedeljković BeleslinUniversity Clinical Center of Serbia, Clinic of Endocrinology, Belgrade, Serbia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Despite commercially improved, standardised routine methods used in medical laboratories, precision laboratory medicine lacks harmonisation of results to make the laboratory result useful for its intended purpose. Furthermore, to obtain reliable laboratory results and precise diagnoses, it is important and recommended that each laboratory confirms the analytical and clinical characteristics of the method used. This study aimed to evaluate the analytical and clinical performance of the IMMULITE®2000 TSI bridge immunoassay to determine autoreactive thyroid stimulating hormone receptor antibodies (SH-R-Ab). Methods: A total of 86 patients with clinically present Graves' orbitopathy and 23 healthy volunteers as a control group were included in the study. The total TSH-R-Ab concentration was determined using an ECLIA (Elecsys Anti-TSHR Immunoassay Roche Diagnostics, GmbH, Mannheim, Germany) on the Cobas e411 analyser (Roche, Diagnostics, GmbH). The TSH-R-Ab concentration was measured using a CLIA method (IMMULITE TSI 2000, Siemens Healthcare Diagnostics, UK). The inaccuracy of the method was investigated using two levels of commercial control samples (low and high analyte concentration). Results: The results obtained meet the general minimum requirements for the analytical performance of laboratory methods (CV<5%). The overall laboratory inaccuracy was acceptable according to FDA guidelines (CV<20%). The results showed a statistically significant correlation between the analysed methods (r=0.9041, p < 0.0001) but with a relative bias of 24.5%. The best ratio of sensitivity and specificity determined by the ROC analysis (93.3% and 100%, respectively) was obtained for a cut-off value of 0.1215 IU/L, which is significantly lower compared to the cut-off value specified by the manufacturer (0.55 IU/L). Conclusions: The IMMULITE 2000 TSI bridge immunoassay for TSH-R-Ab quantification confirmed adequate precision, which is essential for routine use. However, further studies are required to evaluate its analytical specificity.

Indexed as

analytical and clinical sensitivity and specificitythyroid stimulating hormone receptor antibodies